Deployment best practices
Getting the setup right in the field has a direct effect on data quality. These are the things most likely to cause problems if overlooked.
- Sensor orientation: Mount sensors vertically where possible. Horizontal or angled placement can allow air bubbles to form on the sensor face, producing readings that are out of range.
- Water flow around the sensor: Sensors measuring conductivity, pH, or dissolved oxygen need adequate water movement past the sensor head. A protective housing with flow-through holes addresses both protection and flow in one step.
- Physical protection: Loggers deployed in streams, rivers, or tidal zones are exposed to debris, current, and wildlife. Use a protective housing or PVC guard and secure the logger to a fixed anchor point. Record the GPS location or use a visible marker so you can retrieve it reliably.
- Distance from metal: Keep sensors at least 25mm from any metal mounting hardware to avoid interference with readings.
- Well and bore deployments: For 50mm well pipe installations, use a matched well cap with strain relief to protect the cable entry point and keep the logger positioned correctly at depth.
- Calibration before deployment: Water quality sensors measuring DO, conductivity, and pH require calibration before deployment and periodically throughout the monitoring program. Use HOBOware Pro for guided calibration procedures.