OVERVIEW
Flow sensor with integrated flow straightener / no inlet sections necessary
The newly developed VA 525 combines modern digital interfaces for connection to an energy monitoring system with a small, compact design. Due to its reasonable price and modern digital interfaces this compact in-line flow sensor is used when many machines (compressed air consumers) are to be integrated as easily as possible into an energy monitoring network.
The high-contrast, integrated display also displays the current values rotated by 180° if desired (very useful for overhead installation). Depending on the configuration, two of the following values can be displayed:
- Current consumption in m³/h, l / min, …
- Total consumption (meter reading) in m³, l, kg
- Temperature measurement
- Optional: Pressure measurement
Special Features
- Compact, small design – for use in machines, behind maintenance unit at the end user
- Optionally with classic analogue signals (4…20 mA and pulse) or digital interfaces such as Modbus RTU, Ethernet (also PoE), M-Bus
- All interfaces are programmable via the display
-
SPECIFICATIONS
Parameters m³/h, l/min (1000 mbar, 20 °C) in case of compressed air or Nm³/h, Nl/min (1013 mbar, 0 °C) in case of gases Units adjustable via keys at display m³/h, m³/min, l/min, l/s, ft/min, cfm, m/s, kg/h, kg/min, g/s, lb/min, lb/h Sensor Thermal mass flow sensor Measured medium Air, gases Gas types are adjustable over CS service software or CS data logger: Air, nitrogen, argon, CO2 Measuring range See table above Accuracy:
(o. M. V. = of measured
value)
(o. F. S. = of full scale)± 1.5% of m.v. ± 0.3 % of f.s.
on request:
± 1% of m.v. ± 0.3% of f.s. or ± 6% of m.v. ± 0.5% of f.sPressure measurement 0…16 bar, accuracy: 1%, or 10…2000 mbar (abs) Operating temperature -20…60 °C Operating pressure Up to 16 bar Digital output RS 485 interface, (Modbus-RTU), M-Bus (optional) Ethernet interface or PoE Analogue output 4…20 mA for m³/h or l/min Pulse output 1 pulse per m³ or per litre electrically isolated. Pulse weight can be set on the display.
Alternatively, the pulse output can be used as an alarm relaySupply 18…36 VDC, 5 W Burden < 500 Ω Housing Polycarbonate (IP 65) Measuring section Aluminium Connection thread of measuring sections G 1/4″ to G 2″ (BSP British Standard Piping) or 1/2″ to 2″ NPT thread Mounting position any
CS Instruments VA 525 – Compact in-line flow sensor
$0.00 ex GST
Flow sensor with integrated flow straightener / no inlet sections necessary
The newly developed VA 525 combines modern digital interfaces for connection to an energy monitoring system with a small, compact design.