OVERVIEW
CS Instruments FA 510/515 – Dew point sensor for adsorption dryers
Accurate dew point monitoring after an adsorption dryer is essential for energy efficiency, product quality, and protecting downstream equipment. The CS Instruments FA 510/515 is purpose-built for this application, covering a measurement range of -80 to +20°Ctd across all common adsorption dryer types.
Continuously refined sensor technology delivers improved precision across varying ambient temperatures and higher signal resolution, while maintaining the long-term stability and drift resistance the FA series is known for. The condensation-insensitive sensor element is protected by a stainless steel sintered cap.
Output options include 4-20 mA analogue (2- or 3-wire) and Modbus-RTU (RS485). The FA 510 is now also available with IO-Link interface for straightforward integration upstream of machines and systems, and optionally with an integrated pressure sensor.
Details
- Ideal for all types of adsorption dryers with a measuring range of -80…+20°Ctd.
- Gas-independent measurement, also suitable for other, non-corrosive gases
- Compact design, ideal for dryer installations
- Robust design, protection class IP 66
- Condensation insensitive sensor element
- Long-term stability and drift-resistant, thus optimized calibration intervals
- Fast adaptation time, especially from dry to wet conditions
- BSP, NPT or UNF threads
- Analog output 4…20 mA (2- or 3-wire technology) and Modbus RTU (RS 485) interface
- Measured values available in different units, pressure dew point [°Ctd], temperature [°C], rel. humidity [%rh], abs. humidity [g/m³], degree of humidity [g/kg], humidity fraction V/V [ppmV/V], water vapor partial pressure [hPa], atmospheric dew point [°Ctd.atm].
- On-site sensor diagnostics with handheld device or CS Service Software
-
SPECIFICATIONS
Measuring range: See order code Accuracy: ± 1.8 °F at +122…-4 °Ftd
± 3.6 °F at -4…-58 °Ftd
± 5.4 °F at -58…-112 °FtdPressure range: -14.5…700 psi
Special version up to 7250 psiPower supply: 24 VDC (10…36 VDC) Protection class: IP 66 EMC: In acc. with DIN EN 61326-1 Operating temperature: -4…158 °Ftd Connection: M12, 5-pin PC connection: Modbus-RTU, (RS 485),
4…20 mA, 2…10 V, IO-LinkReadable via Modbus: - – Pressure dew point [°Ctd]
- – Temperature [°C]
- – rel. humidity [%rF]
- – abs. humidity [g/m³]
- – Degree of humidity [g/kg]
- – Moisture content V/V
- [ppmV/V]
- – Partial vapor pressure
- [hPa]
- – Atmospheric dew point
- [°Ctd.atm]
- Optional: System pressure [bar(g)]
Burden for analogue output: < 500 Ω Screw-in thread: G 1/2″ Stainless steel
Optional: UNF 5/8″, NPT 1/2″,
NPT 3/8“Dimensions: Ø 30 mm, length approx.
130 mm
CS Instruments FA 510/515 – Adsorption Dryer Dew point sensor (-80 to 20°C )
Dew point sensor for adsorption dryers. Measuring range -80 to +20°Ctd, with 4-20 mA output, Modbus-RTU interface, and IO-Link connectivity.