Project snapshot: an avian influenza biosecurity response
Summary
An Australian emergency animal disease preparedness team needed to see oxygen, temperature and barometric pressure inside a sealed, insulated poultry shed in near real time, from outside. OneTemp put together a wireless solution that carries readings from six points along the shed, plus outside ambient temperature, to a receiving station outside the doors. The system was then put to the test at an industry field day.
The challenge
During controlled atmosphere operations, the response team needs to know conditions inside the shed without going in, and crews need to confirm it’s safe before anyone enters. That means keeping oxygen within the required low range while internal temperature and barometric pressure are monitored continuously, with nitrogen flow adjusted based on readings from six or more points across the shed.
The sheds themselves made that hard. Modern poultry sheds can be up to 150 metres long and 20 metres wide, built from insulated panels around 10 cm thick with metal skins, and the doors stay closed during the operation. Getting a signal out through that is not straightforward. We worked closely with the customer to find the right spot for the RX Manager (analogue mote), so the sensors inside the shed connect reliably and the data reaches LI-COR Cloud for real-time monitoring.
The brief had three other requirements
Readings every 5 minutes, with faster intervals if needed
Conditions visible from outside, with the doors closed
A reliable signal out through metal-skinned insulated panels
Quick to deploy, and easy to wipe down afterwards
The solution
- 6 oxygen sensors with 4 to 20 mA output and replaceable sensor elements
- 6 wireless temperature sensors
- 3 HOBOnet® Analogue Motes that bring the oxygen sensors into the same wireless network
- 1 barometric pressure smart sensor (plug and play, with extension cable)
- 1 ambient temperature smart sensor outside the shed
- A receiving station outside the shed, sending data to LI-COR Cloud
- AC power adapter to charge the receiving station and Analogue Mote batteries
The key was the HOBOnet Analogue Mote. It lets a non-HOBO gas sensor with a standard 4 to 20 mA output connect straight into the HOBO wireless system, so oxygen, temperature and pressure all report to one station and one dashboard. We could choose the right gas sensor for the job, rather than being limited to one range.
The result
The customer organised an industry field day to test the system’s readiness. Liquid nitrogen was injected into the sealed shed while oxygen, internal temperature and barometric pressure were monitored. Readings were logged every five minutes and sent to the cloud every ten, and the team watched the data live on a laptop outside the shed, using a dashboard set up by OneTemp. The trial also checked how the system responded when oxygen reached the safety threshold.
The trial ran for around 30 minutes. In a real operation, monitoring may run for one to two hours, depending on the application.
Use the link to the right to download the Project Snapshot