OVERVIEW
RCD 010 THD is a room Carbon Dioxide (CO2) + Humidity (rH) + Temperature (T) transmitter with colored LCD display to show actual value of each parameter CO2+rH+T.
The combined RCD 010 THD has 3 analogue outputs, i.e. one 0-10 Vdc output for each parameter CO2+rH+T. Selectable ranges for Carbon Dioxide (CO2) + Humidity (rH) + Temperature (T) with DIP switches on pcb.
This device can be used in air conditioning, ventilation and clean room technology, interior rooms such as residential rooms, offices, hotels, technical rooms, meeting rooms and convention centres. It can also be connected with DDC/PLC controller or other automation system such BAS, BMS, BEMS etc
Key Features
- Carbon Dioxide (CO2) output 0-10 Vdc
- Humidity (rH) output 0-10 Vdc
- Temperature (T) output 0-10 Vdc
- LCD display (colored)
- Carbon Dioxide (CO2) sensor
- NDIR Sensor with auto calibration
- Carbon Dioxide (CO2) ranges
- 0-2000 ppm or 0-5000 ppm
- Carbon Dioxide (CO2) accuracy
- ±60 ppm for range 0-2000 ppm ± 2% f.s
- ±150 ppm for range 0-5000 ppm ± 2% f.s
- Temperature (T) accuracy
- ± 0.3°K (+5°C to +60°C) +2.5% f.s.
- Humidity (rH) accuracy
- ± 2% (20 to 80% rH) +2% f.s.
- DIP switch on pcb to select:
- Relative Humidity,
- Absolute Humidity,
- Dew Point or
- Enthalpy
- Passive temperature sensing element
- PT1000, PT100, NTC 10K, NTC 20K, NTC 1.8K , NI1000 etc as option
- VOC sensor output on request
- See all the different types in data sheet.
-
SPECIFICATIONS
Carbon Dioxide (CO2) output 0-10 Vdc Humidity output 0-10 Vdc Temperature output 0-10 Vdc Power supply with 0-10 Vdc output 12-24 Vac/dc Power Consumption 40-100 mA Sensor setting time 60 min Display version LCD Passive temperature sensing element PT1000, PT100, NTC, 10K, NTC 10K, NTC 1.8K, NI1000 etc (option) Carbon Dioxide (CO2) sensor NDIR Sensor with auto calibration Carbon Dioxide (CO2) accuracy ±60ppm ±2% f.s for range 0-2000 ppm
±150ppm ±2% f.s for range 0-5000 ppmHumidity and Temperature sensor Capacative Temperature accuracy ± 0.3°K (+5°C to +60°C) + 2.5% f.s Humidity Accuracy ± 2% (20 to 80% rH) +2% f.s Connection Screw clamps 1.5mm2 Casing Material ABS, COlour RAL 9010 Dimensions Housing (L x W x H) 87,5 x 87,5 x 30mm Protection class IP30 Admissible Environmental conditions 0 to 50°C, 0 to 98% rH Carbon Dioxide (CO2) ranges See configuration page 4 Temperature ranges See configuration page 4 Relative humidity measuring range See configuration page 4 Absolute humidity measuring ranges See configuration page 4 Dew point measuring ranges See configuration page 4 Enthapy range See configuration page 4
VCP RCD 010 THD – CO2, Temp & RH Transmitter w/- Display
$458.00 ex GST
RCD 010 THD is a wall mounted transmitter which combines Carbon Dioxide (CO2) + Humidity (rH) + Temperature (T) with a display