OVERVIEW
Gas Analyser for Emissions Monitoring of Boiler, Engine, & Other Combustion Applications
Accurate / Reliable / Robust / Innovative
- CO Dilution auto-range with measurements to 50,000 ppm
- Total NOx & Low NOx Capable
- Field Replaceable Pre-Calibrated Sensors
- Large Color Touch Screen
- iOS and Android Mobile Apps for Real-Time Display & Control
- Up to six gas sensors
Key features:
- Ergonomic, light weight, & durable design
- Data management with automatic logging & report creation
- Predictive maintenance with estimated sensor life & calibration reminders
- One touch pump On/Off with purge
- PC software with wireless and USB connectivity
- Auto pump cut-off for high CO levels
- Graphical data display
- Customizable gas analysis screen
- Sample conditioning unit for low NOx & high moisture applications
- Stack gas velocity with Pitot tube
- Draft & differential pressure measurements
- Emissions values adjusted for reference O2
- CO & CO2 Monitoring in Ambient Air
- Hose extensions for tall & difficult to reach stacks
- Wireless Printer
- Protective rubber holster
- Maintenance contracts and extended warranties available
-
SPECIFICATIONS
Dimensions 28 x 11.2 x 5.5 cm (11 x 4.3 x 2’’) Weight 825 g (30 oz) Display Color Touch Screen with Graphing; Size: 480 x 272 pixels Keypad 1 On-Off key Material ABS-PC Protection IP42 Connection – Wireless: class 2 range, range frequency from 2402 MHz to 2480 MHz with a transmit power of 1 dBm. Range up to 15 m (50 ft), depending on smartphone radio strength. Minimum required versions: Android 8.0, iOS 12.4, BLE 4.0 Low Energy – USB Power supply Rechargeable battery, USB power supply
Li-Ion 5100 mA/h 3.6 V battery / Power supply voltage of the mains unit: 100-240 Vac, 50-60 Hz
Mains unit: 5 Vdc/2ABattery
Battery life > 8 h; Charging time: Fully charge: < 6.5 h; 50%: < 2.5 h Environmental conditions of use Temperature: from -5 to 45 °C (23 to 113 °F),
Hygrometry: in non-condensing conditions (< 85% RH)
Maximum altitude: 2000 m (6561’)Storage temperature From -20 to 50 °C (-4 to 122 °F) Languages English, French, German, Spanish, Italian, Portuguese European Union Directives 2014/53/EU (RED); 2015/863 EU (RoHS 3) Regulations EN 50379-1 and EN 50379-2; UNI 7129; UNI 11137; UNI 10389; UNI 10845; UL & cUL Certification; BS 7967:2015; BS EN 50543:2011; UNE 60670-10; ES.02173.ES Technical Information
Parameter
Sensor
Measuring range
Resolution
Accuracy(1)
Response time
O2 Electrochemical 0 to 25% 0.01% ±0.2% vol T90 < 30 s
CO (H2 comp.) Electrochemical 0 to 10,000 ppm 1 ppm ±8 ppm < 160 ppm
±5% rdg up to 2000 ppm
±10% rdg > 2000 ppmT90 < 40 s
CO (with dilution) Electrochemical 100 to 50,000 ppm 1 ppm ±10% rdg T90 < 40 s CO2 Calculated 0 to 99.9% 0.1% – – NO (optional) Electrochemical 0 to 5000 ppm 1 ppm ±5 ppm < 100 ppm
±5% rdg > 100 ppmT90 < 40 s Low NO Electrochemical 0 to 300 ppm 0.1 ppm ±5 ppm < 100 ppm
±5% rdg > 100 ppmT90 < 40 s NO2 Electrochemical 0 to 1000 ppm 1 ppm ±5 ppm < 100 ppm
±5 % rdg > 100 ppmT60 < 60 s Low NO2 Electrochemical 0 to 100 ppm 0.1 ppm ±1.5 ppm < 30 ppm
±5% rdg > 30 ppmT60 < 60 s NOx Calculated 0 to 7500 ppm 1 ppm – – Low NOx Calculated 0 to 450 ppm 0.1 ppm – – SO2 Electrochemical 0 to 5000 ppm 1 ppm ±5 ppm < 100 ppm
±5% rdg > 100 ppmT60 < 30 s Low SO2 Electrochemical 0 to 100 ppm 0.1 ppm ±1.5 ppm < 30 ppm
±5% rdg > 30 ppmT60 < 30 s CxHy (HC) Pellistor 0 to 5% 0.01% ± 5% full scale T90 < 40 s H2S Electrochemical 0 to 500 ppm 0.1 ppm ±5 ppm < 100 ppm
±5% rdg > 100 ppmT60 < 35 s Flue temperature TcK -20 to +1250 °C
-4 to +2282 °F0.1 °C
0.1 °F±2 °C or ±0.5% rdg(2)
±3.6 °F or ±0.5% rdg(2)– Air temperature NTC or TcK -20 to +120 °C
-4 to +248 °F0.1 °C
0.1 °F±2 °C
±3.6 °F– Differential temperature Calculated 0 to 1250 °C
0 to 2282 °F0.1 °C
0.1 °F– – Pressure/Draft Semiconductor -200 to +200 mbar
-80 to +80 inH2O0.01 mbar
0.001 inH2O±1% rdg ±0.03 mbar
±1% rdg ±0.012 inH2O– High accuracy draft Semiconductor 500 Pa 0.1 Pa ±0.5 Pa < 10 Pa
±3 Pa up to 150 Pa
±2 % rdg > 150 PaExcess air Calculated 0 to 999% 1% – – Efficiency Calculated 0 to 100% (Gross/HHV(3)) 0.1% – – Efficiency (condensation) Calculated 0 to 125% (Net/LHV(4)) 0.1% – – Stack Gas velocity Calculated 0 to 99 m/s
0 to 19,500 fpm0.1 m/s
1 fpm– -
APP & SOFTWARE
Sauermann Combustion App
The Sauermann Combustion app lets you control your Si-CA analyser remotely, view measurement results in real time, and customise them before exporting in the format of your choice.
- Fast, easy wireless connection
- Remote live view of combustion analysis data as list or graph
- Remote control to change settings
- Data saving, including automatic logging
- Report creation in PDF, CSV (for Excel) and XML formats
- Databases for customers, operators, & equipment
Scan the QR code below to download the app today:
Sauermann Combustion Software (Si-CA 130 & Si-CA 230 ONLY)
The Sauermann Combustion software lets you control your Si-CA 130 and Si-CA 230 analysers remotely, view measurement results in real time, and customise them before exporting in the format of your choice
- Remote live view of combustion analysis data as list or graph
- Remote control to change settings
- Data saving, including automatic logging
- Report creation in PDF, CSV (for Excel) and XML formats
- Databases for customers, operators, & equipment
Download the Software from the Sauermann website here >>
Sauermann Si-CA 230 – Combustion gas analyser
$0.00 ex GST
With double the number of cells and expanded measurement capabilities, the Si-CA 230 is suited to the most powerful industrial machines. And with support for more gases and a high CO tolerance threshold, its versatility makes it the ideal choice across residential, commercial and industrial applications.