OVERVIEW
Get real-time alerts for pressure changes
Indispensable to facility managers, fabricators, pipeline managers, and legacy machine operators, Monnit’s Wireless 300 PSIG Pressure Meter remotely monitors line pressure (gas, liquid, or vapors) up to 300 pounds per square in gauge (PSIG). If the pressure exceeds your preset limits, you receive an email, call, or text alert.
By connecting a Monnit Wireless Pressure Meter to a pressurized gas, liquid, or vapor supply line, you can measure the pressure within the line and review the data in the iMonnit Online Sensor Monitoring and Notification System. The data is stored in the online system and can be reviewed on dashboards and charts, and exported as a data sheet or graph. You can customize settings to your use case and set notifications and alerts in the cloud-based software to know immediately via text, email, or call if the pressure is above or below an optimal range.
Work safely in hazardous environments
Working in industrial environments with potentially explosive atmospheres can be highly hazardous. IECEx is the International Electrotechnical Commission (IEC) System for Certification to Standards Relating to Equipment for Use in Explosive Atmospheres. The IECEx System facilitates international trade in equipment and services used in hazardous areas to address the risk of fires or explosions from flammable gases or dust.
There’s a risk to workers in many industries prone to producing explosive atmospheres. When flammable gases, mist, vapors, or dust mix with air, explosive atmospheres occur, and the slightest spark can set them off. The dangers aren’t only prevalent in the petrochemical industry but also in manufacturing, pharmaceutical, food processing, power generation, construction, architectural woodworking, and more.
Monnit provides a growing IECEx-certified Internet of Things (IoT) product line with award-winning1 ALTA-ISX Wireless Sensors to work safely in hazardous industrial environments within potentially explosive atmospheres.Monnit’s ISX Long-Range Wireless Sensors are IECEx-certified2 under code: Ex ib IIA T3 Gb. Essentially, the IECEx-certified sensors are used in IEC Zone 1 areas where explosive industrial atmospheres of IEC group IIA gases (propane or similar) may be present.
These ALTA-ISX Sensors are not only certified as intrinsically safe in explosive atmospheres of group IIA and hazardous Zone 1 environments, but they’re also:- Incapable of causing a spark or reaching a temperature (class T3) that could ignite an explosive atmosphere comprising a range of group IIA gases or dust
- Able to be used in many industrial applications worldwide where combustible gases (group IIA) may be present in Zone 1 areas
1 Monnit won the 2022 Industrial IoT Product of the Year Award and the 2022 IoT Innovator Award for its ALTA-ISX Sensors.
2 Review an explanation of the IECEx safety code and use requirements in the safety manuals of each Monnit ALTA-ISX Sensor.Features
- Impressive wireless range of up to 1,200 feet through walls
- Frequency-hopping spread spectrum (FHSS)
- Improved interference immunity
- Improved power management for longer battery life
- Encrypt-RF® Security (Diffie-Hellman Key Exchange + AES-128 CBC for sensor data messages)
- Over-the-air updates
- Free iMonnit basic online wireless sensor monitoring and notification system to configure sensors, view data and set alerts via SMS text and email
- Stores 2000 to 4000 readings if gateway connection is lost (non-volatile flash, persists through the power cycle)
- 10-minute heartbeats = ~ 22 days
- 2-hour heartbeats = ~ 266 days
The meter is supplied with a single AA RAMWAY ER14505M battery with a capacity of approximately 2,200 mAh. A single AA RAMWAY ER14505M lithium / thionyl chloride battery MUST be used and ONLY the RAMWAY ER14505 battery.
Applications
- Compressor / compressed air lines
- Water Supply lines
- Gas Supply lines
- Pumping Systems
- Irrigation system pressure
- Industrial Process Monitoring
- Trash Compaction Equipment
- HVAC/R
- Checmical Processing
-
GATEWAY
Gateway Options for Seamless IoT Data Communication
Monnit offers a range of gateway options designed to facilitate wireless sensor data communication within IoT networks. These gateways, serve as crucial conduits for transmitting sensor data to the iMonnit software platform and play a pivotal role in ensuring seamless and efficient data transmission for IoT applications.
Click here to explore the diverse range of gateway devices available >>
-
SOFTWARE
Manage Your Monnit Sensors with iMonnit Cloud-based Software
Monnit’s Sensor Monitoring Software, iMonnit, stands as a cutting-edge cloud-based platform and central hub tailored for the seamless management of Monnit sensors. With a focus on data security, all information is safeguarded on dedicated servers running Microsoft SQL Server. This intuitive online user interface serves as a command centre for arranging, monitoring, and modifying device settings to suit individual requirements.
OneTemp provides complimentary activation and setup services for new iMonnit accounts, while a free mobile app empowers users to maintain control at all times. Whether opting for the basic version or upgrading to iMonnit Premiere, users can unlock the full spectrum of features that enrich the Monnit experience.
Click here to explore the software options >>
-
SPECIFICATIONS
Technical Information
Supply voltage 2.0-3.8 VDC Current consumption 0.2 μA (sleep mode), 0.7 μA (RTC sleep), 570 μA (MCU idle), 2.5 mA (MCU active), 5.5 mA (radio RX mode), 22.6 mA (radio TX mode) Operating temperature range (board circuitry and batteries) -40°C to 40°C (-40°F to 104°F) Data logging Data logs 2000 to 4000 readings if the gateway connection is lost (non-volatile flash, persists through the power cycle):
10-minute Heartbeats = ~ 22 days; 2-hour Heartbeats = ~ 266 daysWireless protocol ALTA Proprietary Frequency-Hopping Spread Spectrum (FHSS) Wireless transmission power 50 mW (900MHz), 25 mW (868 MHz), 10 mW (433 MHz) Wireless antenna type 1/4-wave, 20 gauge wire whip, 3.5″ (900/868MHz), 7″ (433MHz) Wireless range 1,200+ ft non-line-of-sight Resolution 0.1 PSI Security Encrypt-RF® (256-bit key exchange and AES-128 CTR) Weight 8 ounces (226.7 g) Certifications 900 MHz product; FCC ID: ZTL-G2SC1 and IC: 9794A-G2SC1. 868 and 433 MHz product tested and found to comply with: EN 300 220-2 V3.1.1 (2017-02), EN 300 220-2 V3.1.1 (2017-02), and EN 60950.
All sensors: IECEx?Ex ib IIA T3 Gb?Cert # 21.0028X
Monnit IECEx 300 PSIG Pressure Wireless Meter
$1,820.00 ex GST
Remotely monitor gas, liquid, or vapor line pressures up to 300 pounds per square in gauge (PSIG). It provides precise performance over the entire line pressure.
NOTE: Gateway Required for Operation – Refer to Tab Below