OVERVIEW
Features
- Automatic pH calibration – up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)
- 0.01 pH resolution
- Offset and average slope display
- ORP calibration option
- Automatic / manual temperature compensation and temperature calibration function
- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration
- Adjustable reference temperature and temperature coefficient
- Adjustable cell constant and selectable measurement unit
- Conductivity and total dissolved solids (TDS) conversion
- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl
- Two (2) salinity calibration curves: NaCl, Seawater
- Auto log data; built-in memory can store up to 500 data
- Auto shut-off (programmable: up to 30 minutes)
- Auto stable, auto hold, and real time measurement modes
- Calibration alarm (programmable: up to 90 days)
- Built-in electrode holder allows 2 electrodes to be attached
- Monochrome LCD with white LED backlight: 50 x 50 mm
- Phono jack output for connecting the meter to computer for software upgrade only
- Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip
- Powered by 2 x AA batteries
- Packaged with electrodes and calibration solutions in carrying case
- 3 years meter warranty
Meter Kit
PC210-K
Package Details:
- LAQUA PC210 dual channel pH/ORP/Cond/TDS/Res/Sal/Temp meter
- 2 x AA batteries
- Manual and quick guide
- 9652-10D plastic-body, gel-filled pH electrode with integrated temperature sensor
- 9383-10D plastic-body, Ti/Pt black, conductivity probe (k=1.0) with integrated temperature sensor
- pH 4.01 and 7.00 buffers, 1413µS/cm and 12.88 mS/cm conductivity solutions (60ml each)
- Electrode adapter
- Carrying case
PC210-KN: Kit with pH 4.01 and 6.86 NIST buffers (60ml each) is available upon request.
-
SPECIFICATIONS
Model
LAQUA PC210
pH/ORP/Cond/TDS/Res/Sal/Temp (°C/°F)
pH Range -2.00 to 16.00 pH Resolution 0.01 pH Accuracy ± 0.01 pH Calibration Points Up to 5 (USA & NIST), Up to 6 (DIN) Buffer Options USA, NIST, DIN ORP Range ± 2000 mV Resolution 0.1 mV (< ±1000 mV), 1 mV (≥ ±1000 mV) Accuracy ± 0.3 mV (< ±1000 mV), 0.3% of reading (≥ ±1000 mV) Calibration Option Yes Conductivity Range …µS/cm to 200.0 mS/cm (k=1.0) Resolution 0.05% full scale Accuracy ±0.6% full scale; ±1.5% full scale > 18.0 mS/cm Reference Temperature 15 to 30 °C (adjustable) Temperature Coefficient 0.00 to 10.00% (adjustable) Cell Constant 0.1, 1.0, 10.0 (adjustable) Calibration Points Up to 4 (Auto) / Up to 5 (Manual) Unit Setting S/cm, S/m (Auto-ranging) TDS Range …ppm to 100 ppt (TDS factor=0.5) Resolution 0.01 ppm (mg/L) / 0.1 ppt (g/L) Accuracy ±0.1% full scale Calibration Curves Linear (0.40 to 1.00), EN27888, 442, NaCl Resistivity Range 0.000 Ω•cm to 20.0 MΩ•cm Resolution 0.05% full scale Accuracy ±0.6% full scale; ±1.5% full scale > 18.0 MΩ•cm Salinity Range 0.0 to 100.0 ppt / 0.00 to 10.00 % Resolution 0.1 ppt / 0.01 % Accuracy ±0.2% full scale Calibration Curves NaCl, Seawater Calibration Option Yes Temperature Range -30.0 to 130.0 °C / -22.0 to 266.0 °F Resolution 0.1 °C / °F Accuracy ± 0.5 °C / ± 0.9 °F Calibration Option Yes Memory Data 500 Auto Log Data Yes Measurement Modes Auto Stable, Auto Hold, Real Time Offset / Average Slope Display Yes Calibration Alarm Yes (Programmable: up to 90 days) Auto Shut-Off Yes (Programmable: up to 30 minutes) Electrode Status Yes (On screen display) Diagnostic Messages Yes Software Upgrade Yes via PC (USB) cable PN 3200779639 Meter Inputs 2 x BNC (for pH and conductivity electrodes), 2 x phono (for temperature sensors) Meter Output phono (for software upgrade only) Display Custom LCD with backlight Housing IP67, shock & scratch resistant, non-slip Power Requirement 2 x AA batteries Battery Life > 500 hours Meter Dimensions 160 (L) x 80 (W) x 40.60 (H) mm Meter Weight Approx. 260g (with batteries) / 216g (without batteries)
Horiba PC210-K – PH, ORP, EC, TDS, Salinity, Res, Temp Kit
$1,547.00 ex GST
A Portable Meter kit for the measurement of PH/ORP/EC/TDS/Salinity/Res/Temp.