OVERVIEW
Easy to add to HOBO loggers and stations
The Contact Closure Pulse Input Adaptor connects sensors with pulse outputs to loggers with smart-sensor inputs. This smart sensor is compatible with contact closures, such as tipping-bucket rain gauges or reed switches with a maximum input frequency of 2 Hz (2 pulses per second), and a preferred switch-type of normally-open
The pulse input adapters are used to log the number of switch closures per interval and are designed to work with smart sensor-compatible HOBO® loggers and stations. The adapter has a plug-in modular connector that allows it to be added easily to these devices.
Features
- Plug-n-play adapter for pulse output sensors
- Automatically recognized by H21, H22, U30, and ZW data loggers
- Compatible with contact closures, such as tipping-bucket rain gauges or reed switches with a maximum input frequency of 2 Hz (2 pulses per second)
-
SPECIFICATIONS
Maximum Input Frequency 2 Hz (2 pulses per second) Measurememnt Range 0–65,533 pulses per logging interval Resolution 1 pulse Lockout Time 327 ms ±10% Recommended Input Type Mechanical contact closure
(example: reed switch in a
tipping-bucket rain gauge)Preferred Switch State* Normally open Edge Detection Falling edge, Schmitt Trigger buffer (logic levels: low ≤0.6 V, high ≥2.7 V) Minimum Pulse Width 1 ms Input/Output Impedance 100 KΩ Open Circuit Input Voltage 3.3 V Maximum Input Voltage 3.6 V User Connection 24 AWG wires, 2 leads: white(+), black(-) Operating Temperature Range -40° to 75°C (-40° to 167°F) Overall Cable Length 6.5 m (21.3 ft.) or 1.57 m (5.1 ft.) Length of Smart Sensor Cable** 50 cm (1.6 ft.) Housing Weatherproof Xenoy housing protects input adapter electronics Housing Dimensions 12.7 x 2.9 cm (5 x 1.13 in.) Weight S-UCx-M001: 114 g (4 oz.); S-UCx-M006: 250 g (9 oz) Bits per Sample 16 Number of Data Channels 1 Measurement Averaging Option No (reports the number of pulses over the logging interval) CE The CE Marking identifies this product as complying with all relevant directives in the European Union (EU). * For maximum battery life, the pulse input adapters should be used with their preferred switch type. The adapters will
work with active high inputs (S-UCC) and normally closed switches (S-UCD), but battery life will not be optimized.
** A single HOBO station can accommodate 15 data channels and up to 100 m (328 ft) of smart sensor cable (the digital
communications portion of the sensor cables).
HOBO – Contact Closure Pulse Input Adaptors
$213.00 – $234.00 ex GST
The Contact Closure Pulse Input Adaptor connects sensors with pulse outputs to loggers with smart-sensor inputs. This smart sensor is compatible with contact closures, such as tipping-bucket rain gauges or reed switches with a maximum input frequency of 2 Hz (2 pulses per second), and a preferred switch-type of normally-open