OVERVIEW
Know the asphalt temperature while you’re still paving
Asphalt only compacts properly inside its temperature window. A load that has cooled in transit or a cold strip behind the screed shows up later as poor density, and a handheld check at the back of the paver only tells you about one spot at one moment.
The Calex PyroCV is an infrared asphalt temperature sensor built for construction machinery. It mounts on the paver, roller or other vehicle and reads the surface temperature without contact, updating every 125 ms. It’s tested to ISO 13766-1, the EMC standard for earth-moving and building construction machinery.
Features
- Built for construction machinery. EMC tested to ISO 13766-1 and load dump tested to ISO 16750-2 (clamped).
- Rugged housing. 316 stainless steel, sealed to IP67 / IP65 (when mated), and operates in ambient temperatures from -40 to 85 °C.
- Range to suit the job. Choose -20 to 100 °C, 0 to 250 °C or 0 to 500 °C, or a custom span of at least 100 °C within -20 to 500 °C.
- Fast, stable readings. 125 ms response, accuracy of ±1% of reading or ±1 °C, and repeatability of ±0.5% or ±0.5 °C.
- Simple wiring. M12 5-pin connector, 10 to 28.8 V DC supply and a linear 0–5 V output to a display, controller or PLC. CANbus version on request.
- Quick to mount. M18 x 1 mm thread with two mounting nuts supplied, to fit a bracket or cut-out of your own design.
Where it’s used
- Asphalt pavers: mat temperature behind the screed
- Rollers and compactors: surface temperature during compaction
- Concrete processing and curing: surface temperature without contact
- Other non-reflective surfaces: bulk materials, rubber, thick plastics and painted or coated metal
-
INSTALLATION AND WIRING
Installation and wiring
The PyroCV mounts by its M18 x 1 mm thread, using the two nuts supplied, on a bracket or cut-out of your own design. It runs on 10 to 28.8 V DC (20 mA maximum) and connects through an M12 5-pin, A-coded connector. The cable isn’t supplied: Calex suggests a shielded SICK YF2A24-030UB4XLEAX for voltage models and YF2A15-020C1BXLEAX for CAN.
Voltage models (PCV-151-xx-V) CAN models (PCV-151-CAN) Pin Voltage models CAN models 1 Shield Shield 2 PWR+ (10 to 28.8 V DC) PWR+ (10 to 28.8 V DC) 3 PWR- PWR- 4 Voltage output (0–5 V, minimum load 50 kΩ) CAN_H 5 Do not connect CAN_L Installation tips
- Ground at one point only. Either the cable shield or the sensor housing, not both.
- Keep it away from electrical noise. Mount the sensor away from motors, generators and similar equipment.
- Size the target to the spot. With 15:1 optics the spot is 43 mm across at 500 mm and 76 mm at 1 m. Keep the target at least twice the spot size.
- Keep the view clear. Steam, smoke and dust in the line of sight cause errors, and fumes can coat the lens. In dusty or damp positions, fit an air purge collar.
- Let it settle. Allow 20 minutes after a large change in ambient temperature.
Not sure which range or mounting position suits your machine? Talk to us and we’ll work it through with you.
-
SPECIFICATIONS
Measurement Temperature range -20 to 500 °C. Standard ranges: LT -20 to 100 °C, MT 0 to 250 °C, HT 0 to 500 °C. ST: custom span within -20 to 500 °C, minimum 100 °C Spectral range 8 to 14 µm Optics 15:1 (spot 9 mm at the lens, 43 mm at 500 mm, 76 mm at 1,000 mm; 90% energy) Accuracy ±1% of reading or ±1 °C, whichever is greater Repeatability ±0.5% of reading or ±0.5 °C, whichever is greater Emissivity Voltage models: fixed 0.95. CAN models: 0.2 to 1.0, configurable Response time 125 ms (90% response) Startup time 250 ms Electrical Output 0–5 V DC, linear with measured temperature. Raw CANbus on CAN models Supply voltage 10 to 28.8 V DC at the sensor Current draw 20 mA maximum Minimum load resistance 50 kΩ (voltage models) Wiring protection Reverse polarity; shorts to other pins Connector M12 5-pole male, A-coded (cable not supplied) CANbus (CAN models) Message 8 bytes every 200 ms: object temperature and internal sensor temperature (°C, floating point) Baud rate 250 kbps CAN ID 0 to 2047, default 0 Mechanical Housing 316 stainless steel Dimensions 86.5 mm long, 18 mm diameter Mounting M18 x 1 mm thread, 60 mm long, two mounting nuts supplied Weight 90 g Environmental Ingress protection IP67 / IP65 (when mated) Operating ambient -40 to 85 °C, 95% RH maximum, non-condensing Storage temperature -40 to 85 °C Conformity EMC ISO 13766-1. Load dump tested to ISO 16750-2 (clamped); protection against unclamped load dump must be provided at system level Ordering Part numbers Voltage: PCV-151-LT-V, PCV-151-MT-V, PCV-151-HT-V, PCV-151-ST-V (custom range). CAN: PCV-151-CAN Calibration Factory calibrated. A three-point traceable calibration certificate can be ordered with the sensor Warranty 2 years -
FAQ
Does the PyroCV come with a cable?
No. It has an M12 5-pin connector so you can fit a cable to suit your machine, and it comes with two mounting nuts. Use a shielded M12 cable, and ground the sensor at one point only: either the cable shield or the housing.
Which temperature range do I need?
Most asphalt paving and compaction sits inside the MT range (0 to 250 °C). Choose HT (0 to 500 °C) for hotter materials, LT (-20 to 100 °C) for concrete curing and lower-temperature work, or ask for a custom span of at least 100 °C.
How far from the surface can it be mounted?
As far as you need, provided the line of sight is clear of steam, smoke and dust. The spot grows with distance: 43 mm at 500 mm and 76 mm at 1 m. Keep the target at least twice the size of the spot.
Can it measure steel or other shiny metal?
Not reliably. Bare, reflective metal gives false readings. Painted or coated metal is fine, or paint a small area of the target to measure it.
Is a CANbus version available?
Yes, on request (PCV-151-CAN). It sends object and internal sensor temperature every 200 ms, and its emissivity can be set from 0.2 to 1.0. The standard voltage models are fixed at 0.95, which suits asphalt.
Can it be calibrated?
Every sensor is calibrated at manufacture. A three-point traceable calibration certificate can be ordered with the sensor, and existing sensors can be checked and recalibrated. The PyroCV carries a two-year warranty.
Calex PyroCV – Infrared Asphalt Temperature Sensor
A rugged, non-contact infrared temperature sensor built for asphalt pavers, rollers and road construction vehicles. Mount it on the machine, connect power and a display, and read the surface temperature continuously from -20 to 500 °C.
0–5 V output as standard. CANbus version available on request.
Need help choosing a range or mounting position? Contact us or Request a call back
Pricing & Information
Want a price or have a question about this product? Send us an enquiry and our team will get back to you.