OVERVIEW
Dew point sensor from -20 to 50°Ctd for the typical use in refrigeration dryers
Refrigeration dryers are the most common compressed air drying method in industrial settings, and monitoring their output reliably protects equipment and maintains air quality. The CS Instruments FA 510/515 is designed for exactly this application, with a measurement range of -20 to +50°Ctd and accuracy of ±1°C across the full range.
Continuously refined sensor technology and evaluation electronics deliver improved precision across ambient temperature variation and higher signal resolution, without compromising the long-term stability and drift resistance the FA series is known for. The condensation-insensitive sensor element is protected by a stainless steel sintered cap.
Output options include 4-20 mA analogue (2- or 3-wire) and Modbus-RTU (RS485). The FA 510 is now also available with IO-Link interface for easy integration upstream of machines and systems, and optionally with an integrated pressure sensor.
Details:
- Ideal for refrigeration dryer applications with an accuracy of +/- 1°C in the measuring range -20…+50°Ctd.
- Gas-independent measurement, also suitable for other, non-corrosive gases
- Compact design, ideal for dryer installations
- Robust design, protection class IP 66
- Condensation insensitive sensor element
- Long-term stability and drift-resistant, thus optimized calibration intervals
- Fast adaptation time, especially from dry to wet conditions
- BSP, NPT or UNF threads
- Analog output 4…20 mA (two- or three-wire) and Modbus RTU (RS 485) interface
- Measured values available in different units, pressure dew point [°Ctd], temperature [°C], rel. humidity [%rh], abs. humidity [g/m³], degree of humidity [g/kg], humidity fraction V/V [ppmV/V], water vapor partial pressure [hPa], atmospheric dew point [°Ctd.atm].
- On-site sensor diagnostics with handheld device or CS Service Software
-
SPECIFICATIONS
Measuring range: See order code Accuracy: ± 1.8 °F at +122…-4 °Ftd
± 3.6 °F at -4…-58 °Ftd
± 5.4 °F at -58…-112 °FtdPressure range: -14.5…700 psi
Special version up to 7250 psiPower supply: 24 VDC (10…36 VDC) Protection class: IP 66 EMC: In acc. with DIN EN 61326-1 Operating temperature: -4…158 °Ftd Connection: M12, 5-pin PC connection: Modbus-RTU, (RS 485),
4…20 mA, 2…10 V, IO-LinkReadable via Modbus: - – Pressure dew point [°Ctd]
- – Temperature [°C]
- – rel. humidity [%rF]
- – abs. humidity [g/m³]
- – Degree of humidity [g/kg]
- – Moisture content V/V
- [ppmV/V]
- – Partial vapor pressure
- [hPa]
- – Atmospheric dew point
- [°Ctd.atm]
- Optional: System pressure [bar(g)]
Burden for analogue output: < 500 Ω Screw-in thread: G 1/2″ Stainless steel
Optional: UNF 5/8″, NPT 1/2″,
NPT 3/8“Dimensions: Ø 30 mm, length approx.
130 mm