OVERVIEW
Prove your compressed air quality at every point of use
When compressed air touches the product, oil, particles or moisture in the line become a contamination risk, and an audit wants numbers against ISO 8573-1, not a filter change log. Testing usually means three separate instruments, their own setup and three sets of data to line up afterwards.
The CS Instruments All-in-one Solution puts all three measurements in one mobile case: OIL CHECK 500 for residual oil vapour, PC 400 for particles down to 0.1 µm and FA 510 for pressure dew point. The instruments are permanently mounted, plumbed and preconfigured, and the DS 500 chart recorder shows and logs every reading on one 7″ screen.
Features
- Three measurements, one connection. One 2 m PTFE hose with quick coupling feeds the oil, particle and dew point measurement together.
- Down to ISO 8573-1 class 1. Oil vapour detection limit of about 0.001 mg/m³ and particle counting from 0.1 µm, both low enough to check class 1 air.
- Ready to measure. The instruments are preconfigured and talk to each other automatically when powered on. No wiring or setup on site.
- One record for the whole survey. The DS 500 logs every channel to its SD card, with comment fields to name each measuring point, and exports by USB or Ethernet.
- Built to move between sites. Wheeled trolley case, 607 × 275 × 475 mm and about 30 kg, with a built-in pressure reducer, gauge and ball valve.
- Oil- and grease-free sampling. PTFE hose and fittings that won’t contaminate the sample, plus a zero filter for checking the particle counter.
Who it’s for
- Compressed air service companies: air quality audits and dryer or filter checks across customer sites
- Manufacturers testing their own plant: pharmaceutical, food and beverage, electronics and other sites where air touches the product
- Commissioning and troubleshooting: checking new installations, or tracing where contamination enters the network
-
WHAT'S INCLUDED
Everything comes mounted in the case
Item What it does OIL CHECK 500 Measures residual oil vapour content to ISO 8573-5 PC 400 particle counter Counts particles from 0.1 µm to ISO 8573-4 FA 510 dew point sensor Measures pressure dew point down to -80 °Ctd, with integrated pressure measurement DS 500 chart recorder Displays, logs and exports all readings on a 7″ colour touch screen Pressure reducer with gauge and ball valve Sets the sample pressure for the instruments Zero filter Checks the particle counter reads zero with clean air 2 m PTFE connection hose with quick coupling Oil- and grease-free sample line to the measuring point 24 V DC plug-in power supply Powers the whole system from one outlet Wheeled transport case Holds and protects everything between sites Calibration certificate, USB stick and operating instructions Supplied with the system -
WHAT IT MEASURES
Three measurements against ISO 8573-1
Measurement Instrument Range Standard Strictest class it can check Residual oil (vapour) OIL CHECK 500 0.001 to 1 ppm (about 0.003 to 4 mg/m³); detection limit about 0.001 mg/m³ ISO 8573-5 Class 1 (≤ 0.01 mg/m³) Particles PC 400 0.1 to 5 µm in three size channels (0.1–0.5, 0.5–1, 1–5 µm) ISO 8573-4 Class 1 Pressure dew point FA 510 -80 to +20 °Ctd ISO 8573-3 Class 1 (≤ -70 °C) ISO 8573-1 class 1 limits for the oil class cover total oil (aerosol and vapour). The OIL CHECK 500 measures the vapour share.
-
RUNNING A MEASUREMENT
From the compressor room to a logged result in four steps
1Connect
Stand the case on a level surface, connect the PTFE hose to the measuring point (7.2 mm coupling socket) and plug in the power supply.
2Pressurise
Open the ball valve, then the air supply slowly, then switch on. The instruments start and find each other automatically.
3Set the flow
Adjust the pressure reducer until the PC 400 FlowRate on the DS 500 reads 100%, then leak-test the connection.
4Record
Start a new record file on the DS 500, name the measuring point in the comment field, and export by USB or Ethernet when done.
How long to measure. CS recommends at least 60 minutes per measuring point, and 24 hours for the most reliable result. New pipework or a measuring chamber can take up to 24 hours to flush fully.
Unsure about the air at a point? If the line may carry liquid water or oil aerosol, fit a bypass with a suitable filter first, so the sensors aren’t contaminated.
-
SPECIFICATIONS
System Order number 0699 0090 Dimensions (W × H × D) 607 × 275 × 475 mm Weight About 30 kg Power supply 24 V DC plug-in power supply, max. 90 W Sample connection 2 m PTFE hose with quick coupling, for a 7.2 mm coupling socket Operating temperature +5 to +50 °C (recommended +20 to +45 °C) Storage temperature -10 to +60 °C Humidity Max. 80% RH, non-condensing Protection class IP54, indoor use Calibration interval 12 months recommended (start at 6 months for high-accuracy work) OIL CHECK 500 (residual oil) Measuring range 0.001 to 1 ppm (about 0.003 to 4 mg/m³ residual oil, typical) Detection limit About 0.001 mg/m³ Technology Photoionisation detector (PID), patented “Forced Pressure Variation” auto calibration Operating pressure 3 to 9 bar (g) Measured gas flow About 0.5 L/min Medium temperature +20 to +45 °C (short-term +70 °C) Measuring medium Compressed air, nitrogen (other gases on request) PC 400 (particles) Measuring range 0.1 to 5 µm Size channels 0.1–0.5 µm, 0.5–1 µm, 1–5 µm Counting efficiency (ISO 21501-4) 50% at 0.1 µm, 100% above 0.15 µm Maximum concentration 1 million particles per cubic foot Flow rate 28.3 L/min (1 CFM) Zero count < 1 count per 5 minutes (ISO 21501-4) FA 510 (dew point) Measuring range -80 to +20 °Ctd, with integrated pressure sensor Outputs 4–20 mA and Modbus RTU (connected to the DS 500) DS 500 (chart recorder) Display 7″ colour touch screen Data storage 2 GB SD card (up to 4 GB optional) Interfaces USB, Ethernet, RS485 Modbus RTU/TCP; web server optional Alarm outputs 4 relays, freely programmable -
FAQ
Do I need to set anything up before measuring?
No. The instruments are mounted, plumbed and preconfigured at the factory and connect to each other automatically when powered on. On site you connect the hose and power, set the pressure and start recording.
What pressure can it connect to?
The built-in pressure reducer sets the sample pressure for the instruments. The OIL CHECK 500 measures at 3 to 9 bar (g). Tell us your system pressure and we’ll confirm the setup.
Does the OIL CHECK 500 measure total oil?
No. It measures the oil vapour content, to ISO 8573-5. ISO 8573-1 oil classes cover aerosol and vapour together, so aerosol content needs to be assessed separately. Talk to us about your test plan.
How long does a measurement take?
At least 60 minutes per point, with 24 hours giving the most reliable result. New pipework can take up to 24 hours to flush.
How do I get the data off it?
The DS 500 stores readings on its SD card. Export them by USB stick or over Ethernet, with a comment field on each record to identify the measuring point.
How often does it need calibrating?
CS recommends every 12 months, or every 6 months to start with for high-accuracy work. The system ships with a calibration certificate.
CS Instruments All-in-one Solution – Mobile Compressed Air Quality System
A mobile compressed air quality testing system in one wheeled case. Measure residual oil, particles and pressure dew point against ISO 8573-1 at any point of use, and record the results on the built-in DS 500 chart recorder.
OIL CHECK 500, PC 400 and FA 510 permanently mounted and preconfigured: connect the hose and power, and start measuring.
Need help planning an air quality survey? Contact us or Request a call back