OVERVIEW
This transmitter is still available however has been replaced with the: XU2
Features:
- Field Programmable Bi-Polar Input ranges.
 - Isolated Input to Output 2.0kV.
 - High Accuracy.
 - 40~200mV Output Test Signal.
 - LED Indication of Loop Current.
 - Low Cost.
 - Easy to Install.
 - Compact DIN Rail Mount Enclosure.
 - Available Standard or Special Calibration.
 - Reverse Polarity Protection.
 
 - 
                            
SPECIFICATIONS
Input
- -Voltage 10mVdc to 150Vdc and Bipolar. (LPI-D-P is Field Programmable.)
- Minimum Input Resistance = 200k
 - Maximum Over-range = 170Vdc Continuous.
 
 - -Current 200Adc to 100mAdc and Bipolar. (LPI-D-P is Field Programmable.)
- Input Resistance = 25
 - Maximum Overange = 120mAdc Continuous.
 
 - -Damping 3 Second Selectable with H1. (LPI-D-P Only)
 
Output
- -mA 2 wire 4~20mA. (Loop Powered.)
 - -mV Test 40~200mV ±1% @ 4~20mA. Other Test Voltages Available. e.g. 1~5V.
 - Note. mV Test Increases Power Supply & Decreases Load Resistance.
 
Power Supply 8~33Vdc.
Supply Voltage Sensitivity <±0.005%/V FSO.
Output Load Resistance 800 @ 24Vdc. (50/V Above 8Vdc.)
Maximum Output Current Limited to <28mA.
Accurate to <±0.1% FSO Typical.
Linearity & Repeatability <±0.1% FSO Typical.
Ambient Drift <±0.02%/C FSO Typical.
Noise Immunity 125dB CMRR Average. (2.0kVac RMS Limit.)
EMC Compliances Emissions EN 55022-A. Immunity EN 50082-1, <1% Effect FSO Typical.
Isolation Test Voltages 2000Vac/dc Input to Output for 1min.
Response Time 200msec Typical. (10 to 90% 50msec Typical.)
Operating Temperature 0~70C.
Storage Temperature -20~80C.
Operating Humidity 5~85%RH Max. Non-Condensing.
Dimensions and Construction L=79, W=22.5, H=85mm. Polyamide Thermoplastic Rail Mount Enclosure.
 - -Voltage 10mVdc to 150Vdc and Bipolar. (LPI-D-P is Field Programmable.)
 
Intech LPI-D – DC Transmitter
Price range: $375.00 through $453.00 ex GST
The LPI-D has Current or Voltage input with 4-20mA loop powered output.