{"id":8582,"date":"2024-05-03T00:24:12","date_gmt":"2024-05-03T00:24:12","guid":{"rendered":"https:\/\/www.onetemp.com.au\/?post_type=resource&#038;p=8582"},"modified":"2024-06-16T07:21:19","modified_gmt":"2024-06-16T07:21:19","slug":"hobo-dissolved-oxygen-logger-user-manual","status":"publish","type":"resource","link":"https:\/\/www.onetemp.com.au\/nz\/resources\/hobo-dissolved-oxygen-logger-user-manual\/","title":{"rendered":"HOBO Dissolved Oxygen Logger User Manual"},"content":{"rendered":"<p>The HOBO Dissolved Oxygen logger is a standalone logger that uses RDO\u00ae Basic Technology to measure dissolved oxygen (DO). The logger has an optical sensor that provides 0.2 mg\/L accuracy. The logger also features an easily replaceable sensor cap and an integrated temperature sensor. Using HOBOware\u00ae software for logger setup and a HOBO Waterproof Shuttle for quick data offload, this logger is easy to deploy in both freshwater and saltwater environments making it an ideal tool for environmental impact studies as well as ecological and oceanographic research. Using the data offloaded from the logger, the HOBOware Dissolved Oxygen Assistant can calculate percent saturation and salinity-adjusted DO concentration as well as correct for measurement drift from fouling (additional meter or logger measurements required).<\/p>\n<p>To access this valuable resource and enhance your user experience, simply click the link to the right to download the manual.<\/p>","protected":false},"excerpt":{"rendered":"<p>The HOBO Dissolved Oxygen logger is a standalone logger that uses RDO\u00ae Basic Technology to measure dissolved oxygen (DO). The logger has an optical sensor that provides 0.2 mg\/L accuracy. The logger also features an easily replaceable sensor cap and an integrated temperature sensor. Using HOBOware\u00ae software for logger setup and a HOBO Waterproof Shuttle for quick data offload, this logger is easy to deploy in both freshwater and saltwater environments making it an ideal tool for environmental impact studies as well as ecological and oceanographic research. Using the data offloaded from the logger, the HOBOware Dissolved Oxygen Assistant can calculate percent saturation and salinity-adjusted DO concentration as well as correct for measurement drift from fouling (additional meter or logger measurements required).<\/p>\n<p>To access this valuable resource and enhance your user experience, simply click the link to the right to download the manual.<\/p>","protected":false},"template":"","class_list":["post-8582","resource","type-resource","status-publish","hentry","resource-category-user-manuals","manufacturer-resource-hobo-data-loggers"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>HOBO Dissolved Oxygen Logger User Manual - OneTemp<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.onetemp.com.au\/nz\/resources\/hobo-dissolved-oxygen-logger-user-manual\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"HOBO Dissolved Oxygen Logger User Manual - OneTemp\" \/>\n<meta property=\"og:description\" content=\"The HOBO Dissolved Oxygen logger is a standalone logger that uses RDO\u00ae Basic Technology to measure dissolved oxygen (DO). The logger has an optical sensor that provides 0.2 mg\/L accuracy. The logger also features an easily replaceable sensor cap and an integrated temperature sensor. Using HOBOware\u00ae software for logger setup and a HOBO Waterproof Shuttle for quick data offload, this logger is easy to deploy in both freshwater and saltwater environments making it an ideal tool for environmental impact studies as well as ecological and oceanographic research. Using the data offloaded from the logger, the HOBOware Dissolved Oxygen Assistant can calculate percent saturation and salinity-adjusted DO concentration as well as correct for measurement drift from fouling (additional meter or logger measurements required).  To access this valuable resource and enhance your user experience, simply click the link to the right to download the manual.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.onetemp.com.au\/nz\/resources\/hobo-dissolved-oxygen-logger-user-manual\/\" \/>\n<meta property=\"og:site_name\" content=\"OneTemp\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/OneTempAust\/\" \/>\n<meta property=\"article:modified_time\" content=\"2024-06-16T07:21:19+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"HOBO Dissolved Oxygen Logger User Manual - OneTemp","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.onetemp.com.au\/nz\/resources\/hobo-dissolved-oxygen-logger-user-manual\/","og_locale":"en_US","og_type":"article","og_title":"HOBO Dissolved Oxygen Logger User Manual - OneTemp","og_description":"The HOBO Dissolved Oxygen logger is a standalone logger that uses RDO\u00ae Basic Technology to measure dissolved oxygen (DO). The logger has an optical sensor that provides 0.2 mg\/L accuracy. The logger also features an easily replaceable sensor cap and an integrated temperature sensor. Using HOBOware\u00ae software for logger setup and a HOBO Waterproof Shuttle for quick data offload, this logger is easy to deploy in both freshwater and saltwater environments making it an ideal tool for environmental impact studies as well as ecological and oceanographic research. Using the data offloaded from the logger, the HOBOware Dissolved Oxygen Assistant can calculate percent saturation and salinity-adjusted DO concentration as well as correct for measurement drift from fouling (additional meter or logger measurements required).  To access this valuable resource and enhance your user experience, simply click the link to the right to download the manual.","og_url":"https:\/\/www.onetemp.com.au\/nz\/resources\/hobo-dissolved-oxygen-logger-user-manual\/","og_site_name":"OneTemp","article_publisher":"https:\/\/www.facebook.com\/OneTempAust\/","article_modified_time":"2024-06-16T07:21:19+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.onetemp.com.au\/resources\/hobo-dissolved-oxygen-logger-user-manual\/","url":"https:\/\/www.onetemp.com.au\/resources\/hobo-dissolved-oxygen-logger-user-manual\/","name":"HOBO Dissolved Oxygen Logger User Manual - OneTemp","isPartOf":{"@id":"https:\/\/www.onetemp.com.au\/#website"},"datePublished":"2024-05-03T00:24:12+00:00","dateModified":"2024-06-16T07:21:19+00:00","breadcrumb":{"@id":"https:\/\/www.onetemp.com.au\/resources\/hobo-dissolved-oxygen-logger-user-manual\/#breadcrumb"},"inLanguage":"en-NZ","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.onetemp.com.au\/resources\/hobo-dissolved-oxygen-logger-user-manual\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.onetemp.com.au\/resources\/hobo-dissolved-oxygen-logger-user-manual\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"","item":"https:\/\/www.onetemp.com.au\/nz"},{"@type":"ListItem","position":2,"name":"Resources","item":"https:\/\/www.onetemp.com.au\/resources\/"},{"@type":"ListItem","position":3,"name":"HOBO Dissolved Oxygen Logger User Manual"}]},{"@type":"WebSite","@id":"https:\/\/www.onetemp.com.au\/#website","url":"https:\/\/www.onetemp.com.au\/","name":"OneTemp New Zealand","description":"","publisher":{"@id":"https:\/\/www.onetemp.com.au\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.onetemp.com.au\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-NZ"},{"@type":"Organization","@id":"https:\/\/www.onetemp.com.au\/#organization","name":"OneTemp New Zealand","url":"https:\/\/www.onetemp.com.au\/","logo":{"@type":"ImageObject","inLanguage":"en-NZ","@id":"https:\/\/www.onetemp.com.au\/#\/schema\/logo\/image\/","url":"https:\/\/www.onetemp.com.au\/wp-content\/uploads\/2025\/04\/OneTemp-Logo.jpeg","contentUrl":"https:\/\/www.onetemp.com.au\/wp-content\/uploads\/2025\/04\/OneTemp-Logo.jpeg","width":800,"height":153,"caption":"OneTemp"},"image":{"@id":"https:\/\/www.onetemp.com.au\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/OneTempAust\/","https:\/\/au.linkedin.com\/company\/onetemp-pty-ltd"]}]}},"_links":{"self":[{"href":"https:\/\/www.onetemp.com.au\/nz\/wp-json\/wp\/v2\/resource\/8582","targetHints":{"allow":["GET","DELETE"]}}],"collection":[{"href":"https:\/\/www.onetemp.com.au\/nz\/wp-json\/wp\/v2\/resource"}],"about":[{"href":"https:\/\/www.onetemp.com.au\/nz\/wp-json\/wp\/v2\/types\/resource"}],"wp:attachment":[{"href":"https:\/\/www.onetemp.com.au\/nz\/wp-json\/wp\/v2\/media?parent=8582"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}