{"id":10243,"date":"2024-05-27T04:21:42","date_gmt":"2024-05-27T04:21:42","guid":{"rendered":"https:\/\/www.onetemp.com.au\/?post_type=resource&#038;p=10243"},"modified":"2024-05-27T04:40:38","modified_gmt":"2024-05-27T04:40:38","slug":"phionics-linear-conversion-of-conductivity-to-salinity-info-sheet","status":"publish","type":"resource","link":"https:\/\/www.onetemp.com.au\/nz\/resources\/phionics-linear-conversion-of-conductivity-to-salinity-info-sheet\/","title":{"rendered":"pHionics Linear Conversion of Conductivity to Salinity Info Sheet"},"content":{"rendered":"<p>This article provides a simplified means of converting the conductivity of surface seawater (not fresh or brackish water) to salinity for general monitoring purposes. The current standards, PSS-78 and Thermodynamic Equation of Seawater \u2013 2010 (TEOS-10), are available online, but use complicated equations and programs such as MATLAB that are not accessible to everyone.<\/p>\n<p>Conductivity to salinity calculators based on PSS-78 are available online, but very few of them have batch processing capabilities and none can be used when monitoring conductivity in real-time with instruments that require linear scaling(e.g. The HOBO RX3000 with a 4-20 mA sensor). Here, we lay out our logic and method of creating a linear equation that allows temperature-compensated conductivity sensors to estimate salinity of surface seawater (practical salinity values of 22-42 at 0-200 m depth and 5-35\u00b0C) within 5% of the true value. The equation is provided below and the rest of the article explains how it was derived and why there are limitations to its use.<\/p>\n<p>To read the full article, simply click the link to the right to view the document.<\/p>","protected":false},"excerpt":{"rendered":"<p>This article provides a simplified means of converting the conductivity of surface seawater (not fresh or brackish water) to salinity for general monitoring purposes. The current standards, PSS-78 and Thermodynamic Equation of Seawater \u2013 2010 (TEOS-10), are available online, but use complicated equations and programs such as MATLAB that are not accessible to everyone.<\/p>\n<p>Conductivity to salinity calculators based on PSS-78 are available online, but very few of them have batch processing capabilities and none can be used when monitoring conductivity in real-time with instruments that require linear scaling(e.g. The HOBO RX3000 with a 4-20 mA sensor). Here, we lay out our logic and method of creating a linear equation that allows temperature-compensated conductivity sensors to estimate salinity of surface seawater (practical salinity values of 22-42 at 0-200 m depth and 5-35\u00b0C) within 5% of the true value. The equation is provided below and the rest of the article explains how it was derived and why there are limitations to its use.<\/p>\n<p>To read the full article, simply click the link to the right to view the document.<\/p>","protected":false},"template":"","class_list":["post-10243","resource","type-resource","status-publish","hentry","resource-category-datasheets","manufacturer-resource-phionics"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>pHionics Linear Conversion of Conductivity to Salinity Info Sheet - OneTemp<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.onetemp.com.au\/nz\/resources\/phionics-linear-conversion-of-conductivity-to-salinity-info-sheet\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"pHionics Linear Conversion of Conductivity to Salinity Info Sheet - OneTemp\" \/>\n<meta property=\"og:description\" content=\"This article provides a simplified means of converting the conductivity of surface seawater (not fresh or brackish water) to salinity for general monitoring purposes. The current standards, PSS-78 and Thermodynamic Equation of Seawater \u2013 2010 (TEOS-10), are available online, but use complicated equations and programs such as MATLAB that are not accessible to everyone.  Conductivity to salinity calculators based on PSS-78 are available online, but very few of them have batch processing capabilities and none can be used when monitoring conductivity in real-time with instruments that require linear scaling(e.g. The HOBO RX3000 with a 4-20 mA sensor). Here, we lay out our logic and method of creating a linear equation that allows temperature-compensated conductivity sensors to estimate salinity of surface seawater (practical salinity values of 22-42 at 0-200 m depth and 5-35\u00b0C) within 5% of the true value. The equation is provided below and the rest of the article explains how it was derived and why there are limitations to its use.  To read the full article, simply click the link to the right to view the document.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.onetemp.com.au\/nz\/resources\/phionics-linear-conversion-of-conductivity-to-salinity-info-sheet\/\" \/>\n<meta property=\"og:site_name\" content=\"OneTemp\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/OneTempAust\/\" \/>\n<meta property=\"article:modified_time\" content=\"2024-05-27T04:40:38+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"pHionics Linear Conversion of Conductivity to Salinity Info Sheet - OneTemp","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.onetemp.com.au\/nz\/resources\/phionics-linear-conversion-of-conductivity-to-salinity-info-sheet\/","og_locale":"en_US","og_type":"article","og_title":"pHionics Linear Conversion of Conductivity to Salinity Info Sheet - OneTemp","og_description":"This article provides a simplified means of converting the conductivity of surface seawater (not fresh or brackish water) to salinity for general monitoring purposes. The current standards, PSS-78 and Thermodynamic Equation of Seawater \u2013 2010 (TEOS-10), are available online, but use complicated equations and programs such as MATLAB that are not accessible to everyone.  Conductivity to salinity calculators based on PSS-78 are available online, but very few of them have batch processing capabilities and none can be used when monitoring conductivity in real-time with instruments that require linear scaling(e.g. The HOBO RX3000 with a 4-20 mA sensor). Here, we lay out our logic and method of creating a linear equation that allows temperature-compensated conductivity sensors to estimate salinity of surface seawater (practical salinity values of 22-42 at 0-200 m depth and 5-35\u00b0C) within 5% of the true value. The equation is provided below and the rest of the article explains how it was derived and why there are limitations to its use.  To read the full article, simply click the link to the right to view the document.","og_url":"https:\/\/www.onetemp.com.au\/nz\/resources\/phionics-linear-conversion-of-conductivity-to-salinity-info-sheet\/","og_site_name":"OneTemp","article_publisher":"https:\/\/www.facebook.com\/OneTempAust\/","article_modified_time":"2024-05-27T04:40:38+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.onetemp.com.au\/resources\/phionics-linear-conversion-of-conductivity-to-salinity-info-sheet\/","url":"https:\/\/www.onetemp.com.au\/resources\/phionics-linear-conversion-of-conductivity-to-salinity-info-sheet\/","name":"pHionics Linear Conversion of Conductivity to Salinity Info Sheet - OneTemp","isPartOf":{"@id":"https:\/\/www.onetemp.com.au\/#website"},"datePublished":"2024-05-27T04:21:42+00:00","dateModified":"2024-05-27T04:40:38+00:00","breadcrumb":{"@id":"https:\/\/www.onetemp.com.au\/resources\/phionics-linear-conversion-of-conductivity-to-salinity-info-sheet\/#breadcrumb"},"inLanguage":"en-NZ","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.onetemp.com.au\/resources\/phionics-linear-conversion-of-conductivity-to-salinity-info-sheet\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.onetemp.com.au\/resources\/phionics-linear-conversion-of-conductivity-to-salinity-info-sheet\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"","item":"https:\/\/www.onetemp.com.au\/nz"},{"@type":"ListItem","position":2,"name":"Resources","item":"https:\/\/www.onetemp.com.au\/resources\/"},{"@type":"ListItem","position":3,"name":"pHionics Linear Conversion of Conductivity to Salinity Info Sheet"}]},{"@type":"WebSite","@id":"https:\/\/www.onetemp.com.au\/#website","url":"https:\/\/www.onetemp.com.au\/","name":"OneTemp New Zealand","description":"","publisher":{"@id":"https:\/\/www.onetemp.com.au\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.onetemp.com.au\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-NZ"},{"@type":"Organization","@id":"https:\/\/www.onetemp.com.au\/#organization","name":"OneTemp New Zealand","url":"https:\/\/www.onetemp.com.au\/","logo":{"@type":"ImageObject","inLanguage":"en-NZ","@id":"https:\/\/www.onetemp.com.au\/#\/schema\/logo\/image\/","url":"https:\/\/www.onetemp.com.au\/wp-content\/uploads\/2025\/04\/OneTemp-Logo.jpeg","contentUrl":"https:\/\/www.onetemp.com.au\/wp-content\/uploads\/2025\/04\/OneTemp-Logo.jpeg","width":800,"height":153,"caption":"OneTemp"},"image":{"@id":"https:\/\/www.onetemp.com.au\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/OneTempAust\/","https:\/\/au.linkedin.com\/company\/onetemp-pty-ltd"]}]}},"_links":{"self":[{"href":"https:\/\/www.onetemp.com.au\/nz\/wp-json\/wp\/v2\/resource\/10243","targetHints":{"allow":["GET","DELETE"]}}],"collection":[{"href":"https:\/\/www.onetemp.com.au\/nz\/wp-json\/wp\/v2\/resource"}],"about":[{"href":"https:\/\/www.onetemp.com.au\/nz\/wp-json\/wp\/v2\/types\/resource"}],"wp:attachment":[{"href":"https:\/\/www.onetemp.com.au\/nz\/wp-json\/wp\/v2\/media?parent=10243"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}