Monnit Enterprise Resistance Wireless Sensor

Manufacturer:
Monnit’s Industrial Resistance Sensor reads the resistance across any resistive load and reports back the measured resistance.
Part Number: MNS2-4-W2-RS-ST-L03
Back to Previous Page
$409.00 ex GST
i h

Instant alerts for passive resistive loads

A popular transducer interface solution for passive resistance loads up to 250K Ohms, Monnit’s sensors awake at user-specified times to monitor a resistive load. Captured analog data is then calculated into a resistance measurement. If the observed resistance deviates from user-set thresholds, the user is notified via text, email, or call. Instant alerts prevent unnecessary (and costly) downtime or the loss of research and irreplaceable samples.

Monnit’s Industrial Resistance Sensors can be retrofitted quickly to scientific sensors or equipment, such as batteries, that are used in the process and manufacturing sectors.

Monnit’s Industrial Resistance Sensor reads the resistance across any resistive load and reports back the measured resistance. The resistance sensor leads are meant to connect to passive devices only, connecting the sensor leads to any voltage or power source may damage the sensor. It is programmed to sleep for a user-given time interval (heartbeat) and then wake up, convert the analog data, mathematically compute the resistance, and transmit the data to the gateway, where it is then logged into the cloud service. The user can configure defined thresholds and have the system alert on threshold breaches.

This sensor come standard with two replaceable AA batteries. The typical battery life is approximately 10 years.


Features

  • Impressive wireless range of up to 1,200 feet through walls
  • Frequency-hopping spread spectrum (FHSS)
  • Improved interference immunity
  • Improved power management for longer battery life
  • Encrypt-RF® Security (Diffie-Hellman Key Exchange + AES-128 CBC for sensor data messages)
  • Stores 2000 to 4000 readings if gateway connection is lost (non-volatile flash, persists through the power cycle)
    • 10-minute heartbeats = ~ 22 days
    • 2-hour heartbeats = ~ 266 days
  • Over-the-air updates
  • Free iMonnit basic online wireless sensor monitoring and notification system to configure sensors, view data and set alerts via SMS text and email


Applications

  • Resistance Monitoring 
  • Battery Monitoring 
  • Transducer Interfacing 
  • Elevator Monitoring


IMPORTANT - Sensor Operation

Please note: this sensor requires both an applicable Gateway and iMonnit software to operate. For further information, please refer to the tabs above or related products below.


Installing the Monnit ALTA Resistance Sensor

This simple video tutorial will walk you through how to install the new ALTA Resistance Sensor on iMonnit. 


Monnit Gateway Options

An integral component of any IoT network is the gateway. A gateway device allows for data from sensors to be transmitted to the iMonnit software platform.


Monnit Ethernet Wireless Gateway 4

Monnit’s Ethernet Gateways allow your Monnit Wireless Sensors to communicate with the iMonnit™ Online Wireless Sensor Monitoring and Notification System without the need for a PC. Simply provide power and plug the gateway into an open Ethernet network port with an internet connection. It will then automatically connect with our online servers, providing the perfect solution for commercial locations where there is an active internet connection.

Learn more about the Ethernet Wireless Gateway 4>>



Monnit 4G + Ethernet IoT Gateway

The ALTA® by Monnit Wireless IoT Gateway combines a 4G LTE CAT-M1/NB2 cellular engine and Ethernet platform with Monnit’s wireless access point network to aggregate and communicate data from Monnit ALTA Wireless Sensors. The ALTA IoT Gateway allows ALTA Sensors to operate on the world’s leading cellular networks and stay connected to the Internet. The gateway uses AC main power but also has redundant power through a battery backup lasting up to 60 hours.

To meet the global demand for enterprise IoT deployment, the IoT Gateway communicates with the cloud-based iMonnit® monitoring software via cellular transmission, making it ideal for remote locations or where the Internet isn’t available. The RJ-45 Ethernet jack allows local device configuration, diagnostics, and connectivity backup. The IoT Gateway is instrumental in sending sensor notifications via text, email, or call if user-defined conditions are met or exceeded.

Learn more about the 4G + Ethernet Wireless Gateway 4>>


Online Sensor Monitoring Software

iMonnit is a cloud based mobile internet platform and central hub for managing Monnit and ALTA products. All data is secured on dedicated servers operating Microsoft SQL Server. This online user interface is where all your device settings can be arranged, supervised, and modified to reflect your unique environment. OneTemp will look after the activation and setup of your new online iMonnit account free of charge. There is also a free mobile app for you to stay in control at all times. Start with the basic version or upgrade to iMonnit Premiere to enjoy the full features your Monnit experience can offer.


iMonnit Basic Vs Premiere:

  • Basic - Free with no ongoing costs
    Monnit Basic is included for free with all wireless sensors, providing basic features for you to configure and monitor your sensors online. These basic features only support one network and one registered user on an account.
  • Premiere - Minimal Annual Fee
    iMonnit Premiere allows for enhanced functionality of your wireless sensors and includes an advanced software feature set at a low annual cost. All of iMonnit's advanced features are availble for configuration. You can have more sensors on your account, support multiple users, and view floorplans for all your sensors.

Learn more about the iMonnit Premier Online Software>>

 


Technical Information

Supply Voltage 2.0 - 3.6 VDC (3.0 - 3.6 VDC Using Power Supply) *
Current Consumption 0.2 μA (sleep mode), 0.7 μA (RTC sleep), 570 μA (MCU idle), 2.5
mA (MCU active), 5.5 mA (radio RX mode), 22.6 mA (radio TX
mode)
Operating Temperature Range (board circuitry and battery) -18°C to 55°C (0°F to 130°F) using alkaline
-40°C to 85°C (-40°F to 185°F) using lithium **
Optimal Battery Temperature Range (AA) +10°C to +50°C ( +50°F to +122°F )
Resistive Range (in Ohms) 0 - 250000
Specific Resistive Ranges (in Ohms) 0 - 5600, 5600 - 250000
Resolution (in Ohms) 65535 Unique Values Per Specific Range (16 bit):
~3.4, ~125
Accuracy +/- 3% FS of Specific Range
User Calibrated Accuracy +/- 2% FS of Specific Range
Lead Wire Length 1ft. (12 in.)
Wireless Range 1,200+ ft non-line-of-sight
Security Encrypt-RF® (256-bit key exchange and AES-128 CTR)
Weight 3.1 ounces
Enclosure Rating NEMA 1, 2, 4, 4x, 12 and 13 rated, sealed and weather proof
UL Rating UL Listed to UL508-4x specifications (File E194432)
Certifications 900 MHz product; FCC ID: ZTL-G2SC1 and IC: 9794A-G2SC1.
868 and 433 MHz product tested and found to comply with: EN
300 220-2 V3.1.1 (2017-02), EN 300 220-2 V3.1.1 (2017-02) and
EN 60950

*Hardware cannot withstand negative voltage. Please take care when connecting a power device.
**At temperatures above 100°C, it is possible for the board circuitry to lose programmed memory.

Instant alerts for passive resistive loads

A popular transducer interface solution for passive resistance loads up to 250K Ohms, Monnit’s sensors awake at user-specified times to monitor a resistive load. Captured analog data is then calculated into a resistance measurement. If the observed resistance deviates from user-set thresholds, the user is notified via text, email, or call. Instant alerts prevent unnecessary (and costly) downtime or the loss of research and irreplaceable samples.

Monnit’s Industrial Resistance Sensors can be retrofitted quickly to scientific sensors or equipment, such as batteries, that are used in the process and manufacturing sectors.

Monnit’s Industrial Resistance Sensor reads the resistance across any resistive load and reports back the measured resistance. The resistance sensor leads are meant to connect to passive devices only, connecting the sensor leads to any voltage or power source may damage the sensor. It is programmed to sleep for a user-given time interval (heartbeat) and then wake up, convert the analog data, mathematically compute the resistance, and transmit the data to the gateway, where it is then logged into the cloud service. The user can configure defined thresholds and have the system alert on threshold breaches.

This sensor come standard with two replaceable AA batteries. The typical battery life is approximately 10 years.


Features

  • Impressive wireless range of up to 1,200 feet through walls
  • Frequency-hopping spread spectrum (FHSS)
  • Improved interference immunity
  • Improved power management for longer battery life
  • Encrypt-RF® Security (Diffie-Hellman Key Exchange + AES-128 CBC for sensor data messages)
  • Stores 2000 to 4000 readings if gateway connection is lost (non-volatile flash, persists through the power cycle)
    • 10-minute heartbeats = ~ 22 days
    • 2-hour heartbeats = ~ 266 days
  • Over-the-air updates
  • Free iMonnit basic online wireless sensor monitoring and notification system to configure sensors, view data and set alerts via SMS text and email


Applications

  • Resistance Monitoring 
  • Battery Monitoring 
  • Transducer Interfacing 
  • Elevator Monitoring


IMPORTANT - Sensor Operation

Please note: this sensor requires both an applicable Gateway and iMonnit software to operate. For further information, please refer to the tabs above or related products below.