Search
Menu Close

External Input Cable to Measure DC Voltage: For 0-2.5, 5, 10, 24VDC, CABLE-ADAP and CABLE-2.5-STEREO

Manufacturer:
The CABLE-ADAPX and External Input Cable to Measure DC Voltage: CABLE-ADAP and CABLE-2.5-STEREO are external input cables providing analogue sensor input of 0-2.5Vdc, 0-5Vdc 0-10Vdc, 0-24Vdc max. for HOBO ZW Series data nodes, UX120, and U12 series data loggers with one or more analog inputs.
Part Number: CABLE-ADAP5, CABLE-ADAP10, CABLE-ADAP24, CABLE-2.5-STEREO
*
Back to Previous Page
$18.00 ex GST
i h

The CABLE-ADAP and CABLE-2.5-STEREO is an external input cable providing analog sensor input of 0-5 Vdc max. for HOBO ZW Series data nodesUX120, and U12 series data loggers with one or more analog inputs. The cable has 13mm (0.5") tinned braided wire leads and a total length 1.9m (6.3 ft.).

Environment:
The Sensor is for use in Indoor environments

Measurements:
The CABLE-ADAP and CABLE-2.5-STEREO Sensor supports the following measurements:

DC Voltage
 
Models:
  • CABLE-2.5-STEREO 0-2.5VDC
  • CABLE-ADAP5 0-5VDC
  • CABLE-ADAPT10 0-10VDC
  • CABLE-ADAPT24 0-24VDC

CABLE-2.5-STEREO 0-2.5VDC

Input Range: 0 to 2.5 VDC
Accuracy w/U12: ±2 mV ±2.5% of absolute reading
Accuracy w/UX120-006M: ±0.1 mV ±0.1% of absolute reading
Accuracy w/ZW: ±1.5 mV ±2% of reading typical
Resolution w/U12 and ZW: 0.03% of full scale
Resolution w/UX120-006M: : 0.002% of full scale
Length: 1.8 m (6 foot) cable with 13 mm (0.5 in.) tinned braided wire leads

CABLE-ADAP5 0-5VDC

Max. Input: 0–5 VDC
Accuracy with U12: ±4 mV ±2.7% of reading
Accuracy with ZW: ±3.1 mV ±2.2%
Accuracy with UX120-006M: ±0.2 mV ±0.3% of reading
Impedance: 20 K ohm
Resolution with U12 and ZW: 0.03% of full scale
Resolution with UX120-006M: 0.002% of full scale
Length: 1.9 m (6.3 ft) (all models)
Weight: 38.6 g (1.4 oz) (all models)

CABLE-ADAPT10 0-10VDC

Max. Input: 0–10 VDC
Accuracy with U12:±8 mV ±2.7% of reading
Accuracy with ZW: ±6.2 mV ±2.2%
Accuracy with UX120-006M: ±0.4 mV ±0.3% of reading
Impedance: 20 K ohm
Resolution with U12 and ZW: 0.03% of full scale
Resolution with UX120-006M: 0.002% of full scale
Length: 1.9 m (6.3 ft) (all models)
Weight: 38.6 g (1.4 oz) (all models)

CABLE-ADAPT24 0-24VDC

Max. Input: 0–24 VDC
Accuracy with U12: ±20 mV ±2.7% of reading
Accuracy with ZW: N/A
Accuracy with UX120-006M: ±1.0 mV ±0.3% of reading
Impedance: 48 K ohm
Resolution with U12 and ZW: 0.03% of full scale
Resolution with UX120-006M: 0.002% of full scale
Length: 1.9 m (6.3 ft) (all models)
Weight: 38.6 g (1.4 oz) (all models)

*
*
*

The CABLE-ADAP and CABLE-2.5-STEREO is an external input cable providing analog sensor input of 0-5 Vdc max. for HOBO ZW Series data nodesUX120, and U12 series data loggers with one or more analog inputs. The cable has 13mm (0.5") tinned braided wire leads and a total length 1.9m (6.3 ft.).

Environment:
The Sensor is for use in Indoor environments

Measurements:
The CABLE-ADAP and CABLE-2.5-STEREO Sensor supports the following measurements:

DC Voltage
 
Models:
  • CABLE-2.5-STEREO 0-2.5VDC
  • CABLE-ADAP5 0-5VDC
  • CABLE-ADAPT10 0-10VDC
  • CABLE-ADAPT24 0-24VDC
Customers who bought this item also bought

Split-core AC Current Sensor - CTV

A split-core AC current sensor with models over the range of 0 to 600 amps AC for use with HOBO UX120-006, U12 and ZW data loggers with external input channels.
$221.00 ex GST

HOBO UX120 4-Channel Analogue Data Logger - UX120-006M

The HOBO UX120-006M Analogue Logger is a high-performance, LCD display data logger with high accuracy support up to four external sensors
$242.00 ex GST

4-20 mA Input Cable - CABLE-4-20mA

Cable for connecting sensor with 4-20mA ouptut to HOBO U and X Series external-channel data loggers
$44.00 ex GST