Search
Menu Close

Cement

Manufacturer:
LAND have supplied the Cement Industry and OEM's throughout the world with temperature measuring equipment for over 60 years. All our products are designed to the highest standards of quality and reliability to ensure accurate measurements under plant operating conditions.
Part Number: Cement
Back to Previous Page
Product Files
Call for pricing

LAND have supplied the Cement Industry and OEM's throughout the world with temperature measuring equipment for over 60 years. All our products are designed to the highest standards of quality and reliability to ensure accurate measurements under plant operating conditions.

The schematic diagram below illustrates typical features of a cement works. The areas highlighted offer measurement reference points and offers the best choice of instrument, where LAND's infrared thermometry know-how can really benefit you. If your specific area of concern is not covered here, our engineers will be pleased to discuss your requirements with you.

1. Kiln Shell Temperature

Kiln_shell_temperature%20

The early detection of hot or cold spots is vital to avoid costly maintenance or an unplanned shutdown. Continuous monitoring of the kiln shell along its length day and night will provide the earliest possible indication of potential problem spots.

 

2. Rotary Kiln Product Temperature

Rotary_kiln_product_temperature

Sighting tubes of different lengths are installed in various kiln positions - the radiation thermometer accurately measures the temperature at the end of the tube once very kiln rotation. Depending on the thermometer location either the solids (for product quality) or the gases (for kiln efficiency) within the kiln can be measured.

 
 

3. Rotary Kiln Burning Zone Temperature

Rotary_kiln_burning_zone_temperature

Measurement of the temperature in the kiln burning zone is vital for maintaining both product quality and kiln efficiency. A 2-colour (ratio) thermometer is used to overcome the inherent problems of dust etc. which obscure the thermometer sight path. This system can be applied equally to both wet and dry processes.

 
 

4. Cement Clinker System Temperature

Cement_clinker_system_temperature

To safeguard against either fire or belt burn out the clinker in the bucket elevator must be sufficiently cooled prior to reaching the rubber conveyor. A thermometer used in a closed control system monitors the temperature of the clinker before it reaches the conveyor. This system sets the cooling levels and improves operating efficiency.

Experts in temperature measurement, AMETEK Land has supported the global industrial community for more than 70 years, supplying innovative, reliable products and solutions. We have a worldwide reputation as innovators and manufacturers of high-quality, precision thermometers and thermal imagers.

Click here to open Land Infrared's Industries Solutions page

(opens in a new tab)

*
*
*

LAND have supplied the Cement Industry and OEM's throughout the world with temperature measuring equipment for over 60 years. All our products are designed to the highest standards of quality and reliability to ensure accurate measurements under plant operating conditions.

The schematic diagram below illustrates typical features of a cement works. The areas highlighted offer measurement reference points and offers the best choice of instrument, where LAND's infrared thermometry know-how can really benefit you. If your specific area of concern is not covered here, our engineers will be pleased to discuss your requirements with you.

1. Kiln Shell Temperature

Kiln_shell_temperature%20

The early detection of hot or cold spots is vital to avoid costly maintenance or an unplanned shutdown. Continuous monitoring of the kiln shell along its length day and night will provide the earliest possible indication of potential problem spots.

 

2. Rotary Kiln Product Temperature

Rotary_kiln_product_temperature

Sighting tubes of different lengths are installed in various kiln positions - the radiation thermometer accurately measures the temperature at the end of the tube once very kiln rotation. Depending on the thermometer location either the solids (for product quality) or the gases (for kiln efficiency) within the kiln can be measured.

 
 

3. Rotary Kiln Burning Zone Temperature

Rotary_kiln_burning_zone_temperature

Measurement of the temperature in the kiln burning zone is vital for maintaining both product quality and kiln efficiency. A 2-colour (ratio) thermometer is used to overcome the inherent problems of dust etc. which obscure the thermometer sight path. This system can be applied equally to both wet and dry processes.

 
 

4. Cement Clinker System Temperature

Cement_clinker_system_temperature

To safeguard against either fire or belt burn out the clinker in the bucket elevator must be sufficiently cooled prior to reaching the rubber conveyor. A thermometer used in a closed control system monitors the temperature of the clinker before it reaches the conveyor. This system sets the cooling levels and improves operating efficiency.