Looking for a DATA LOGGER? Now see – www.hobodataloggers.com.au

VCP CO2 + Temp + RH Transmitter with Display - RCD 010 T

RCD 010 THD is a wall mounted combined Carbon Dioxide (CO2) + Humidity (rH) + Temperature (T) transmitter with display
Part Number: RCD 010 THD
$528.00 ex GST
[$580.80 inc GST]
Product Files

Room CO2+T+rH transmitter with Display
RCD 010 THD

RCD 010 THD is a wall mounted combined Carbon Dioxide (CO2) + Humidity (rH) + Temperature (T) transmitter with display to show the value of each parameter at the same time.

There are 3 analogue outputs, i.e. one 0-10 Vdc output for each parameter.

Ideal for use in air conditioning, ventilation and clean room technology, residential rooms, offices, hotels, technical rooms, meeting rooms and convention centers.


Features

• Carbon Dioxide (CO2) output 0-10 Vdc

• Humidity (rH) output 0-10 Vdc

• Temperature (T) output 0-10 Vdc

• With Display

• Carbon Dioxide (CO2) sensor NDIR Sensor with auto calibration

• Carbon Dioxide (CO2) ranges 0-2000 ppm or 800 to 1200 ppm, jumper selectable

• Carbon Dioxide (CO2) accuracy ±50 ppm ± 4% (25°C / 1013 mbar)

• Temperature (T) accuracy ± 0.5°K (+10°C to +40°C)

• Humidity (rH) accuracy ± 2% (20 to 80% rH)

• DIP switch on pcb to select:
- Relative Humidity,
- Absolute Humidity, 
- Dew Point or
- Enthalpy

 

Room CO2+T+rH transmitter with Display
RCD 010 THD

RCD 010 THD is a wall mounted combined Carbon Dioxide (CO2) + Humidity (rH) + Temperature (T) transmitter with display to show the value of each parameter at the same time.

There are 3 analogue outputs, i.e. one 0-10 Vdc output for each parameter.

Ideal for use in air conditioning, ventilation and clean room technology, residential rooms, offices, hotels, technical rooms, meeting rooms and convention centers.


Features

• Carbon Dioxide (CO2) output 0-10 Vdc

• Humidity (rH) output 0-10 Vdc

• Temperature (T) output 0-10 Vdc

• With Display

• Carbon Dioxide (CO2) sensor NDIR Sensor with auto calibration

• Carbon Dioxide (CO2) ranges 0-2000 ppm or 800 to 1200 ppm, jumper selectable

• Carbon Dioxide (CO2) accuracy ±50 ppm ± 4% (25°C / 1013 mbar)

• Temperature (T) accuracy ± 0.5°K (+10°C to +40°C)

• Humidity (rH) accuracy ± 2% (20 to 80% rH)

• DIP switch on pcb to select:
- Relative Humidity,
- Absolute Humidity, 
- Dew Point or
- Enthalpy

 

Technical data

Carbon Dioxide (CO2) output 0-10 Vdc
Humidity output 0-10 Vdc
Temperature output 0-10 Vdc
Power supply with 0-10 Vdc output: 12-24 Vdc (3-wire)
Analogue output load 0-10 Vdc: 10 to100 kOhm
Power supply with 4-20 mA output: 12-24 Vdc (3-wire)
Analogue output load 4-20 mA 250 to 600 kOhm
Power consumption 9 mA
Display version with E-paper display
Passive temperature sensing element PT1000, PT100, NTC 10K, NTC 10K, NTC 1.8K , NI1000 etc (option)
Carbon Dioxide (CO2) sensor NDIR Sensor with auto calibration
Carbon Dioxide (CO2) accuracy
(after operating 72 h and daily supply of fresh air, min 1 h.)
±50 ppm ± 4% (25°C / 1013 mbar)
Temperature accuracy ± 0.5K ( 10°C to +40°C)
Humidity accuracy ± 2% (20 to 80% rH)
Connection Screw clamps 1,5 mm²
Casing Material ABS,   Colour RAL 9010
Dimensions Housing (L x W x H):   87,5 x 87,5 x 30 mm
Protection class: IP30
Carbon Dioxide (CO2) ranges: see configuration page 7
Temperature ranges: see configuration page 7
Relative humidity measuring range: see configuration page 7
Absolute humidity measuring ranges: see configuration page 7
Dew point measuring ranges : see configuration page 7
Enthalpy range: see configuration page 7

Directive

Electromagn. EMC 2014/30/EU
Low voltage LVD 2014/35/EU
Standards EN 60730-1 2011
EN 60730-2-9 2011
EN14597