Looking for a DATA LOGGER? Now see – www.hobodataloggers.com.au

PyroMiniUSB Infrared Temperature Sensor for Benchtop, Laboratory and Education

Miniature non-contact temperature sensor with USB communications for temperatures from -20°C to 1000°C
Part Number: PyroMiniUSB
Delivery date: 2-3 weeks
*
$341.00 ex GST
[$375.10 inc GST]
Product Files

Sensor Features

  • Miniature non-contact temperature sensor with USB communications
  • Measures temperatures from -20°C to 1000°C
  • USB cable and software included for data logging and configuration
  • Modbus protocol - use your own software to communicate with the sensor

Software Features: CalexConfig

  • Temperature display, graph, configuration and data logging
  • Connect multiple sensors to the same software
  • Simple, touch-friendly interface
  • Software included with every sensor

Typical Applications

Benchtop and Laboratory

With the precision and robustness of our industrial pyrometers, and the plug-and-play convenience of USB, the PyroMiniUSB is the ideal benchtop temperature sensor for testing and experimentation.

Education

The PyroMiniUSB is ideal for teaching science concepts such as emissivity, reflectivity, thermal conductivity, energy transfer, insulation and internal energy.

Calibration Checking

Combined with a blackbody calibration source, the PyroMiniUSB makes the ideal calibration reference pyrometer. Keep one in your calibration room and check the performance of your other sensors against it. Calex can provide calibration certificates for traceabillity.

Ordering

Two models are available:

PMU21     PyroMiniUSB sensor with 2:1 optics – for large or close-up targets

PMU201   PyroMiniUSB sensor with 20:1 optics – for small or more distant targets

Installation

Just plug the sensor directly into the USB port of a PC or laptop.

The sensor is USB powered – no other power supply is required

Sensor Features

  • Miniature non-contact temperature sensor with USB communications
  • Measures temperatures from -20°C to 1000°C
  • USB cable and software included for data logging and configuration
  • Modbus protocol - use your own software to communicate with the sensor

Software Features: CalexConfig

  • Temperature display, graph, configuration and data logging
  • Connect multiple sensors to the same software
  • Simple, touch-friendly interface
  • Software included with every sensor

Typical Applications

Benchtop and Laboratory

With the precision and robustness of our industrial pyrometers, and the plug-and-play convenience of USB, the PyroMiniUSB is the ideal benchtop temperature sensor for testing and experimentation.

Education

The PyroMiniUSB is ideal for teaching science concepts such as emissivity, reflectivity, thermal conductivity, energy transfer, insulation and internal energy.

Calibration Checking

Combined with a blackbody calibration source, the PyroMiniUSB makes the ideal calibration reference pyrometer. Keep one in your calibration room and check the performance of your other sensors against it. Calex can provide calibration certificates for traceabillity.

Ordering

Two models are available:

PMU21     PyroMiniUSB sensor with 2:1 optics – for large or close-up targets

PMU201   PyroMiniUSB sensor with 20:1 optics – for small or more distant targets

Installation

Just plug the sensor directly into the USB port of a PC or laptop.

The sensor is USB powered – no other power supply is required

General Specifications

Temperature Range
-20°C to 1000°C
Interface
RS485 Modbus RTU
Accuracy
±1% of reading or ±1ºC whichever is greater
Repeatability
± 0.5% of reading or ± 0.5°C whichever is greater
Emissivity
0.2 to 1.0
Response Time, t90
125 ms (90% response)
Spectral Range
8 to 14 μm
Supply Voltage
6 to 28 V DC
Supply Current
50 mA max.
Baud Rate
9600 baud (other configurations available upon request)
Modbus Data Format
8 data bits, no parity, 1 stop bit (other configurations available upon request)
Protocol
Modbus over Serial Line

Configuration

Configuration Method
Via USB using CalexConfig or other Modbus software
Configurable Parameters
Emissivity Setting, Averaging, Peak/Valley Hold Processing, Reflected Energy Compensation

Field of View Diagrams

 
Please note: The given measured spot size contains 90% of the energy detected by the sensor. We normally recommend the target is at least twice as large as the given measured spot for maximum accuracy. Sensors may be used at longer distances than the above diagrams show. There is no maximum measurement distance in clean air; this is because Calex sensors detect only the wavelengths of infrared radiation that are not absorbed by the atmosphere.

Mechanical Specifications

Construction
Stainless Steel
Dimensions
18 mm diameter x 45 mm long (excluding cable gland)
Thread Mounting
M16 x 1 mm pitch
Cable Length
1.5 m
Weight with Cable
85 g

Environmental Specifications

Environmental Rating IP65
Ambient Temperature Range          0°C to 75°C
Relative Humidity 95% max. non-condensing

Electromagnetic Compatibility Standards

 
EN61326-1, EN61326-2-3 (Electrical Equipment for Measurement, Control and Laboratory Use – EMC Requirements – Industrial)