Search
Menu Close

Intech XU2HI - Head Mount Transmitter - RTD+Thermocouple Input, 4-20mA Output

Manufacturer:
Suitable for head mounting on RTD and Thermocouple Temperature Sensors to convert the signal to 4-20mA (Loop Powered, This model Features a Zero trim pot for in field calibration and is also Isolated.
Part Number: XU2HI
*
Back to Previous Page
Product Files
$230.00 ex GST
i h

Features:

  • Programmable via USB (requires the XU-USB programming key).
  • No power supply or calibration required during programming.
  • Zero trim pot for in field calibration
  • Temperature Input Types:
    • RTD Pt100 and Pt1000.
    • Thermocouple B, E, J, K, N, R, S, T.
    • Output is Linear with Temperature.
  • High Accuracy 0.1%.
  • Compact Industrial Head Mount Enclosure.
  • Reverse Polarity Protection.
  • Easy to Install.
  • Low Cost.

USB Programmable RTD or Thermocouple Temperature Input.
Standard = RTD Pt100, 0~100°C Input; Upscale; 4~20mA Output (Loop Powered).
Input to Output Isolation 3750Vac.
Heartbeat Status LED.
Case Temperature range -20°C to +85°C.

USB Programming Key
Note: the same XU-USB can be used to program any of the XU Series Transmitters - just change the included cable type for DIN or In-Head!

Note: Requires the XU-USB programming key.
Download the Free Programming Software

Intech Instruments XU process transmitters

Process transmitter which can be programmed using a software program and special usb cable. The transmitter does not need to be powered or require any calibration after completion

  • Output 2 wire 4~20mA / or 20~4mA - Loop Powered.
  • Power Supply 9.5~36Vdc.
  • Supply Voltage Sensitivity <±0.005%/V FSO.
  • Output Load Resistance 700Ω @ 24Vdc. (50Ω/V Above 9.5Vdc.)
  • Maximum Output Current Limited to <28mA.
  • EMC Emissions Compliance EN 61326
  • EMC Immunity Compliance EN 61326
  • Safety Compliance EN 61010-1
  • Accurate to <±0.03% FSO Typical.
  • Linearity & Repeatability <±0.02% FSO Typical. (Unless Individual Specifications State Otherwise)
  • Ambient Drift <±0.003%/C FSO Typical.
  • Noise Immunity 125dB CMRR Average. (2.0k Vdc Limit.)
  • R.F. Immunity <1% Effect FSO Typical.
  • Signal Isolation Voltage Between Input and Output 3750Vac for 1 min. (Excluding XU2HN)
  • Response Time 400msec Typical. (From 10 to 90% 300msec Typical.)
  • Sensor Fail Low 3.8mA, High 21mA
  • Startup Time 3 seconds, 3.7mA output
  • Output calibrate via Pot ±0.5mA Zero offset adjust. (Excluding XU2HN)
  • Operating Temperature -20~85°C (XU2HN: -20~55°C)
  • Storage Temperature -20~100°C
  • Operating Humidity 5~85%RH Max. Non-Condensing.
  • Mounting 35mm Symmetrical Mounting Rail. In Head mount for XU2HI & XU2HN
  • Dimensions XU2: H=79, W=20, D=68mm. / XU2HI & XU2HN: H=44, W=44, D=23mm.

Features:

  • Programmable via USB (requires the XU-USB programming key).
  • No power supply or calibration required during programming.
  • Zero trim pot for in field calibration
  • Temperature Input Types:
    • RTD Pt100 and Pt1000.
    • Thermocouple B, E, J, K, N, R, S, T.
    • Output is Linear with Temperature.
  • High Accuracy 0.1%.
  • Compact Industrial Head Mount Enclosure.
  • Reverse Polarity Protection.
  • Easy to Install.
  • Low Cost.

USB Programmable RTD or Thermocouple Temperature Input.
Standard = RTD Pt100, 0~100°C Input; Upscale; 4~20mA Output (Loop Powered).
Input to Output Isolation 3750Vac.
Heartbeat Status LED.
Case Temperature range -20°C to +85°C.

USB Programming Key
Note: the same XU-USB can be used to program any of the XU Series Transmitters - just change the included cable type for DIN or In-Head!