Looking for a DATA LOGGER? Now see – www.hobodataloggers.com.au

kWh Monitoring Kit - KIT-UX90-KWH

The HOBO kWh Monitoring Kit combines the convenience and affordability of Onset’s award-winning HOBO UX90 State/Pulse Logger with the power of industry-leading WattNode sensors.
Part Number: KIT-UX90-KWH
*
*
*
*
$0.00 ex GST
[$0.00 inc GST]

The HOBO kWh Monitoring Kit combines the convenience and affordability of Onset’s award-winning HOBO UX90 State/Pulse Logger with the power of industry-leading WattNode sensors.

As one of the industry’s lowest-cost kWh monitoring solutions, the kit gives energy engineers, auditors, building commissioners, and others a simple way to log electric usage and is ideal for use in commercial, industrial, and residential applications..

Key advantages:

  • Flexibility to log up to 500,000 single or three phase measurements running 240 to 480 volts
  • LCD display to enable easy viewing of latest kWh readings
  • Priced significantly less than meter-based solutions
  • HOBOware Pro software (priced separately) for easy logger set-up and scaling of kWh measurement data
     

The kit, which can be custom-configured on OneTemps’s website, includes a HOBO UX90 State/Pulse data logger, WattNode kWh transducer, one or more current transducers, and voltage leads.

Environment:
The KIT-UX90-KWH Kit is for use in Indoor environments

Measurements:
The KIT-UX90-KWH Kit supports the following measurements: Kilowatt Hours (kWh)

See specific items for detailed information:

HOBO UX90-001 Data Loggers (Required)

ACT Split Core CT's (1 or 3 Required for single or three phaes)

HOBOware Software (Required if you don't already have this)

Voltage Input Lead Set (Optional for quick connect)

Wattnode Pulse Energy Transducer (required)

Wattnode Models: Please choose carefully or just call us if your not sure.

ModelVAC Phase
to Neutral
VAC Phase
to Phase
Electrical
Service Types
Neutral
Required
WNB-3Y-400-P 230 400 1 Phase 2 Wire 230V with neutral
3 Phase 4 Wire 230V/400V
Yes
WNB-3D-400-P See Below 400 3-Phase 3-Wire Delta 400V (No neutral)
3-Phase 4-Wire Wye 230/400V
 
  • Delta models, WNB-3D-400-P, work either with or without a neutral connection, but require a line-to-line voltage connection for operating power.

The HOBO kWh Monitoring Kit combines the convenience and affordability of Onset’s award-winning HOBO UX90 State/Pulse Logger with the power of industry-leading WattNode sensors.

As one of the industry’s lowest-cost kWh monitoring solutions, the kit gives energy engineers, auditors, building commissioners, and others a simple way to log electric usage and is ideal for use in commercial, industrial, and residential applications..

Key advantages:

  • Flexibility to log up to 500,000 single or three phase measurements running 240 to 480 volts
  • LCD display to enable easy viewing of latest kWh readings
  • Priced significantly less than meter-based solutions
  • HOBOware Pro software (priced separately) for easy logger set-up and scaling of kWh measurement data
     

The kit, which can be custom-configured on OneTemps’s website, includes a HOBO UX90 State/Pulse data logger, WattNode kWh transducer, one or more current transducers, and voltage leads.

Environment:
The KIT-UX90-KWH Kit is for use in Indoor environments

Measurements:
The KIT-UX90-KWH Kit supports the following measurements: Kilowatt Hours (kWh)

See specific items for detailed information:

HOBO UX90-001 Data Loggers (Required)

ACT Split Core CT's (1 or 3 Required for single or three phaes)

HOBOware Software (Required if you don't already have this)

Voltage Input Lead Set (Optional for quick connect)

Wattnode Pulse Energy Transducer (required)

Wattnode Models: Please choose carefully or just call us if your not sure.

ModelVAC Phase
to Neutral
VAC Phase
to Phase
Electrical
Service Types
Neutral
Required
WNB-3Y-400-P 230 400 1 Phase 2 Wire 230V with neutral
3 Phase 4 Wire 230V/400V
Yes
WNB-3D-400-P See Below 400 3-Phase 3-Wire Delta 400V (No neutral)
3-Phase 4-Wire Wye 230/400V
 
  • Delta models, WNB-3D-400-P, work either with or without a neutral connection, but require a line-to-line voltage connection for operating power.

How to configure the HOBO UX90-001 data logger as part of the kWh Kit

How to configure the HOBO UX90-001 data logger as part of the kWh Kit

See specific items for detailed information:

HOBO UX90-001 Data Loggers (Required)

ACT Split Core CT's (1 or 3 Required for single or three phaes)

HOBOware Software (Required if you don't already have this)

Voltage Input Lead Set (Optional for quick connect)

Wattnode Pulse Energy Transducer (required)

Wattnode Models: Please choose carefully or just call us if your not sure.

ModelVAC Phase
to Neutral
VAC Phase
to Phase
Electrical
Service Types
Neutral
Required
WNB-3Y-400-P 230 400 1 Phase 2 Wire 230V with neutral
3 Phase 4 Wire 230V/400V
Yes
WNB-3D-400-P See Below 400 3-Phase 3-Wire Delta 400V (No neutral)
3-Phase 4-Wire Wye 230/400V
  • Delta models, WNB-3D-400-P, work either with or without a neutral connection, but require a line-to-line voltage connection for operating power.