Intech IN-HWD (rev 2) - Humidity and Temperature Indicator/Transmitter:

The IN-HWD (rev 2) has two 4~20mA outputs – humidity and temperature, with no software required.
Part Number: IN-HWD
$1,040.00 ex GST
[$1,144.00 inc GST]

Features:

  • Independent Temperature and Relative Humidity Outputs.
  • %RH Accurate to 1.0%.
  • Temperature Accurate to 0.1%.
  • Low Cost.
  • Easy to Install.
  • Typically used with our WDT-DW wet and dry bulb humidity tank.
  • Replaces the 2100-A4-HWD and the OLD IN-HWD.

Optional: The IN-HWD will connect to our MicroScan SCADA software on the RS485 Modbus comms
(requires the PLC Modbus driver for direct connection to MicroScan; otherwise connect via a Intech Micro I/O Remote Station) for logging of the humidity and temperature.

Ordering Information:

IN-HWD

Input, 1 x wet bulb and 1 x dry bulb.
Standard; RTD Pt100, 3 wire DIN (0~100ºC).

Output, 1 x humidity and 1 x temperature.
2 channels; 4~20mA.
Resolution; 0.025% Full scale. 12 bit.

Indicator; Dual LED screens for humidity and temperature.
Comms; Isolated RS485, RS232 optional.
Power supply options; High: 85~264Vac or 95~370Vdc.
Low: 10~72Vdc or 15~48Vac.

Connection Example:

 

Features:

  • Independent Temperature and Relative Humidity Outputs.
  • %RH Accurate to 1.0%.
  • Temperature Accurate to 0.1%.
  • Low Cost.
  • Easy to Install.
  • Typically used with our WDT-DW wet and dry bulb humidity tank.
  • Replaces the 2100-A4-HWD and the OLD IN-HWD.

Optional: The IN-HWD will connect to our MicroScan SCADA software on the RS485 Modbus comms
(requires the PLC Modbus driver for direct connection to MicroScan; otherwise connect via a Intech Micro I/O Remote Station) for logging of the humidity and temperature.

Ordering Information:

IN-HWD

Input, 1 x wet bulb and 1 x dry bulb.
Standard; RTD Pt100, 3 wire DIN (0~100ºC).

Output, 1 x humidity and 1 x temperature.
2 channels; 4~20mA.
Resolution; 0.025% Full scale. 12 bit.

Indicator; Dual LED screens for humidity and temperature.
Comms; Isolated RS485, RS232 optional.
Power supply options; High: 85~264Vac or 95~370Vdc.
Low: 10~72Vdc or 15~48Vac.

Connection Example:

 

Also see install manual PDF for full specifications

Specifications.

Input 1 x wet bulb, 1 x dry bulb.
Dual 3-wire RTD Pt100 DIN (JIS option).
Power supply HV: 85~265Vac / 95~370Vdc.
LV: 15~48Vac / 10~72Vdc.
Analogue Output Temperature and humidity output. Dual 16-bit 4~20mA (fully scalable). Window
programmable over any range within the full-scale range of the controller.
Sampling rate 2.5Hz.
Resolution 0.025% full scale 16-bit.
Accuracy 0.05% of reading.
Temperature drift Typically 50ppm/°C.
Temperature units °C or °F.
Easy Setup Intuitive text prompts for easy setup.
Calibration Precalibrated for Pt100 RTD. Simple recalibration (if required) using high and low
display values.
Security Calibration and setpoint functions have independent security code access.
Setpoint functions are independently configurable, and accessible through the F2 key.
OPTIONAL
Relay Output 4x 5A Form A relays.
Serial port
Isolated RS232 or RS485.
Modes: ASCII, Modbus RTU