STANDARD FEATURES
Portable and very compact combustion gas analyzer housed in a rugged aluminum case
Measurement of: 
O2 Oxygen, CO Carbon Monoxide, TG Flue-gas temperature, NO Nitric oxide(14090/14190), SO2 (14091/14191)
ASME/BImSchV - Calculation: 
Combustion efficiency,Losses,Excess Air, CO2 Carbon Dioxide
7 Fuels are programmed – 5 fuels are programmable
Automatic zero calibration
 Integrated self check program
 Simultaneous display of eight parameters on the illuminated display
Unit selection : ppm - mg - mg(ref O2) – mg/kWh
Gas sampling probe E – length 0.8 ft (250mm) , hose 8 ft (2.5m)
Rechargeable battery
Thermal printer (14100 / 14190 / 14191)
Power supply 110VAC/60Hz or 230VAC/50Hz
OPTIONAL FEATURES
Ambient air temperature probe
NO-measurement (14090 / 14190)
Gas sampling probe with heated handle
SO2-measurement (14091 / 14191)
Gas sampling probes with different lengths
NO2-measurement
Electronic controlled soot measurement
HC-measurement
RS 232 interface
CO-bypass valve with purging pump
Memory for 200 measurements
12V DC power jack
Draft measurement
 
 

 

IMR 1400 – compact has been designed to measure flue gases Boiler, Burner and Engine Applications and has been developed to meet the customers need and to fulfil special applications.

It is a high quality combustion gas analyzer using the latest sensor technology 

It is easy to use and will measure all the important parameters to adjust and optimize the combustion process.

STANDARD FEATURES
Portable and very compact combustion gas analyzer housed in a rugged aluminum case
Measurement of: 
O2 Oxygen, CO Carbon Monoxide, TG Flue-gas temperature, NO Nitric oxide(14090/14190), SO2 (14091/14191)
ASME/BImSchV - Calculation: 
Combustion efficiency,Losses,Excess Air, CO2 Carbon Dioxide
7 Fuels are programmed – 5 fuels are programmable
Automatic zero calibration
 Integrated self check program
 Simultaneous display of eight parameters on the illuminated display
Unit selection : ppm - mg - mg(ref O2) – mg/kWh
Gas sampling probe E – length 0.8 ft (250mm) , hose 8 ft (2.5m)
Rechargeable battery
Thermal printer (14100 / 14190 / 14191)
Power supply 110VAC/60Hz or 230VAC/50Hz
OPTIONAL FEATURES
Ambient air temperature probe
NO-measurement (14090 / 14190)
Gas sampling probe with heated handle
SO2-measurement (14091 / 14191)
Gas sampling probes with different lengths
NO2-measurement
Electronic controlled soot measurement
HC-measurement
RS 232 interface
CO-bypass valve with purging pump
Memory for 200 measurements
12V DC power jack
Draft measurement
 
 

 

TECHNICAL DATA

PARAMETER PRINCIPLE RESOLUTION ACCURACY RANGE STANDARD
O2 Oxygen Electro-chemical  0.1 Vol.% ± 0.2 % 0-20.9Vol. %
ü
CO Carbon monoxide Electro-chemical  1 ppm 5 %  0-2,000ppm
ü
COp Carbon monoxide-corrected Calculation 1 ppm 5 %    ü
NO Nitric oxide Electro-chemical  1 ppm 5 % 0-,2000 ppm 14090/14190
NO2 Nitric dioxide  Electro-chemical  1 ppm 5 % 0- 100 ppm  
SO2 Sulfur dioxide Electro-chemical  1 ppm 5 % 0-4,000 ppm 14091/14191
HC Hydrocarbons   0.1%  5 % 0-100% LEL  
TG Flue gas temperature NiCr-Ni thermocouple 1 K ± 2 % -4° F / 2192°F 
-20°C..1200°C
ü
TA Air temperature Semiconductor 1 K ± 0.5 K -4° F / 248° F 
-20°C..120°C
 
P Draft Solid state 0.004" H2O 
0.01 hPa
± 2 % - 12" / 20" H2O 
-30hPa/+50hPa
 
CO2 Carbon dioxide Calculation 0.1 Vol.% ± 0.2 % 0- CO2max
ü
Efficiency / ETA Calculation 1 % ± 0.5 % 0-999 %
ü
Losses / qA Calculation 1 % ± 0.5 % 0-999 %
ü
Excess Air/LAMBDA Calculation 1 % ± 2 % 0-999 %
ü
Soot Filter paper method        

Other measurement ranges are available upon request 
Equipped with max 4 sensors 


SPECIFICATION
Dimensions wxdxh:  
1400C:               12"(305mm) x 9"(228mm) x 4.6"(116mm) 
1400C/P (printer):   16"(425mm) x 7"(185mm) x 11" (290mm)
Weight:  
1400C:               approx. 6.7lbs. (2.9kg) 
1400C/P (printer):   approx. 15lbs.  (5.8kg)
MODEL PART-NO.
IMR 1400-c     O2, CO 14000
IMR 1400-c     O2,CO, NO 14090
IMR 1400-c     O2,CO, SO2 14091
IMR 1400-cp    O2,CO 14100
IMR 1400-cp    O2,CO, NO 14190
IMR 1400-cp    O2,CO, SO2 14191
 