Graphtec GL900-8 High Speed 8 Channel Data Logger

Graphtec GL900 is a 8 Channel Data Logger for High Speed Data Logging applications
Part Number: GL900-8
$4,325.00 ex GST
[$4,757.50 inc GST]
Product Files

Graphtec GL900-8

  • Type: High speed general purpose data logger / Paperless recorder.
  • Channels: 8.
  • Inputs: Voltage, Current*, Temperature, Humidity and Logic I/O.
  • Speed: 10µs to 1min. All eight channels simultaneously.
  • Resolution: 16bit.
  • Data Storage:
    • Internal RAM (>10μs): Up to 1 million readings per channel.
    • Internal Flash (>1ms): Up to 300 million readings.
    • External: USB device, max file size is 2GB.
  • PC Connection: Ethernet & USB.
  • Data transfer: USB memory device or direct to PC.
  • Power: Internal Battery or External 12~24 volts DC.
  • Software: Software included.

In compliance with various test requirements, this data logger is capable of performing high-speed simultaneous voltage and temperature measurements

To download the software, click here


Easy-to-use upright high-speed isolated 8-channel multifunction logger

An easy-to-use upright device enabling isolated 8-channel multifunction input, the GL900 is capable of performing high-speed simultaneous measurements of voltage, temperature, and various other phenomena.

VOLTAGE +/-20 mV to +/-500 V
TEMPERATURE Thermocouples:
K, J, E, T, R, S, B, N, W
HUMIDITY 0 to 100%
(the B-530 option is required)
PULSE 4 channels
Count, Inst., Rpm
LOGIC 4 channels
‡ Select either Pulse or Logic

*) The input signal needs to be not exceeding the specified voltage at any time.
The component in the amplifire of the unit may have the damage by over voltage.
Please check the details of over voltage in the specification sheet (Maximum input voltage or Withstand voltage seccion) or the caution label attached on the unit.


Data can be captured to PC-friendly USB memory sticks

Long-term data can be captured directly to built-in 256-MB flash memory or to an external USB memory stick at sampling intervals of from 1 ms to 1 min. For high-speed sampling at intervals faster than 1 ms, up to one million data points can be captured to internal RAM.

Example of 8-channel analog measurement

Capture destination10μs100μs500μs1ms10ms100ms1s
Internal RAM
(up to one million points)
10 seconds Approx. 1 min. and 40 sec. Approx. 8 min. and 20 sec. Approx. 16 min. and 40 sec. Approx. 2 hrs. and 40 sec. Approx. 1 day and 3 hrs. Approx. 11 days and 13 hrs.
Internal flash memory (256 MB) × × × Approx. 1 hour. Approx. 11 hrs. Approx. 4 days Approx. 46 days
External USB memory stick (512 MB) × × × Approx. 22 hrs. Approx. 22 hrs. Approx. 9 days Approx. 93 days

The USB memory stick must be a standard model (without fingerprint recognition or other proprietary features)


 

Can be used as an X-Y recorder

The GL900 reproduces analog X-Y recorder movements and provides the illusion of pen up/pen down movements. It can be operated like an analog X-Y recorder and can also be used as a 4-pen X-Y recorder. The digital data format facilitates post-measurement confirmation of data values and report creation.


High-precision temperature measurement even during high-speed sampling

Lets users perform high-precision temperature measurements even during high-speed sampling – ideal for performing combined voltage and temperature measurements.


Comprehensive built-in trigger and timer functions

Using a combination of trigger and timer functions eliminates superfluous data and enables capture of only the required data.

Setting example 1

To perform measurement over a four-day period starting January 10
Timer setting Date and time Start setting January 10 00 hours 00 minutes
Stop setting January 14 23 hours 59 minutes
Trigger setting Start trigger Off
Stop trigger Off

Setting example 2

To perform measurements of abnormal signals during device operations
Timer setting Daily cycle Start setting 09 hours 00 minutes
Stop setting 17 hours 00 minutes
Trigger setting Start trigger Level CH 1 (3 V Rising)
Stop trigger Level CH 1 (2 V Falling)
Repeat On

Setting example 3

To perform measurements every 20 minutes
Timer setting Hourly cycle Start setting 00 minutes 00 seconds
Stop setting 20 minutes 00 seconds
Trigger setting Start trigger Off
Stop trigger Off

Setting example 4

To perform measurements for a period of one hour, every four hours, daily

With the timer set to daily cycle status, data is captured repeatedly for one hour every four hours.

Trigger setting Start trigger Off
Stop trigger Scheduled time (one hour)
Repeat On (Repeat interval: 4 hours)
Timer settings Timer mode Off, Date and time, Daily cycle, Hourly cycle
Trigger settings Start source setting Off, Level value, External input
Stop source setting Off, Level value, External input, Scheduled time
Pre-trigger 0-100%
Repeat capture On, Off and Repeat interval

High-voltage measurement capability

The wide 500 V range enables 100 to 240 VAC power supply voltage waveform measurements. Using logic input and a clamp meter simultaneously allows measurement of a device’s power supply voltage and current concurrently with sequential control of various points.


Built-in, large-format 5.7-inch color LCD for easy-to-read waveforms

The bright, easy-to-read large-format 5.7-inch color TFT LCD provides vivid, easy-to-read waveform displays. Cursor keys enable fast, easy control and setup. The waveform display can be scrolled at high-speed – 10 ms/DIV.


Free Running display for waveform-checking without the need for data capture

The Free Running display lets users check input signal waveforms even before measurements begin. Since waveforms are displayed on each setup screen, users can make settings while viewing the waveforms.


Easy PC measurement via USB; remote monitoring via Ethernet web server and FTP functions

The USB and Ethernet connections enable transfer of captured data to your PC and setup and control of the GL900 from a PC, even without the PC software provided standard with the GL900.

Web server/FTP server functions

Waveform display and GL900 setup operations can be performed via a web browser (e.g., Internet Explorer). In addition, data files captured to the GL900’s internal memory or to a USB memory stick can be transferred or deleted from the PC.

USB drive mode

When your GL900 is connected to your PC via the USB interface, the GL900 can be operated in USB mode to enable fast, easy data transfers from internal memory to the PC.

NTP client function

Simply connect the GL900 to an NTP server via an Ethernet connection to synchronize GL900 time with NTP server time at periodic intervals


 

Dedicated software for real-time data capture

Three measurement screens are provided to allow selection of the screen that best suits measurement needs.
The Replay screen provides a Zoom screen feature to enable enlarged display of specific sections of long-term measurement data.


 

Simple operations for anyone

Easy-to-use software using icon keys for intuitive operations


Convenient functions

Various convenient data-processing functions are built in.

  • Direct to Excel function
    This function enables measurement data to be written directly to an Excel file.
  • Search function
    This function enables searching for specific values in the captured data.
  • CSV batch conversion function
    This function enables batch conversion of multiple captured files to CSV file format.
  • Thumbnail function
    This function enables display of captured data files as thumbnails.

 

 

 

Graphtec GL900-8

  • Type: High speed general purpose data logger / Paperless recorder.
  • Channels: 8.
  • Inputs: Voltage, Current*, Temperature, Humidity and Logic I/O.
  • Speed: 10µs to 1min. All eight channels simultaneously.
  • Resolution: 16bit.
  • Data Storage:
    • Internal RAM (>10μs): Up to 1 million readings per channel.
    • Internal Flash (>1ms): Up to 300 million readings.
    • External: USB device, max file size is 2GB.
  • PC Connection: Ethernet & USB.
  • Data transfer: USB memory device or direct to PC.
  • Power: Internal Battery or External 12~24 volts DC.
  • Software: Software included.

In compliance with various test requirements, this data logger is capable of performing high-speed simultaneous voltage and temperature measurements

To download the software, click here


Easy-to-use upright high-speed isolated 8-channel multifunction logger

An easy-to-use upright device enabling isolated 8-channel multifunction input, the GL900 is capable of performing high-speed simultaneous measurements of voltage, temperature, and various other phenomena.

VOLTAGE +/-20 mV to +/-500 V
TEMPERATURE Thermocouples:
K, J, E, T, R, S, B, N, W
HUMIDITY 0 to 100%
(the B-530 option is required)
PULSE 4 channels
Count, Inst., Rpm
LOGIC 4 channels
‡ Select either Pulse or Logic

*) The input signal needs to be not exceeding the specified voltage at any time.
The component in the amplifire of the unit may have the damage by over voltage.
Please check the details of over voltage in the specification sheet (Maximum input voltage or Withstand voltage seccion) or the caution label attached on the unit.


Data can be captured to PC-friendly USB memory sticks

Long-term data can be captured directly to built-in 256-MB flash memory or to an external USB memory stick at sampling intervals of from 1 ms to 1 min. For high-speed sampling at intervals faster than 1 ms, up to one million data points can be captured to internal RAM.

Example of 8-channel analog measurement

Capture destination10μs100μs500μs1ms10ms100ms1s
Internal RAM
(up to one million points)
10 seconds Approx. 1 min. and 40 sec. Approx. 8 min. and 20 sec. Approx. 16 min. and 40 sec. Approx. 2 hrs. and 40 sec. Approx. 1 day and 3 hrs. Approx. 11 days and 13 hrs.
Internal flash memory (256 MB) × × × Approx. 1 hour. Approx. 11 hrs. Approx. 4 days Approx. 46 days
External USB memory stick (512 MB) × × × Approx. 22 hrs. Approx. 22 hrs. Approx. 9 days Approx. 93 days

The USB memory stick must be a standard model (without fingerprint recognition or other proprietary features)


 

Can be used as an X-Y recorder

The GL900 reproduces analog X-Y recorder movements and provides the illusion of pen up/pen down movements. It can be operated like an analog X-Y recorder and can also be used as a 4-pen X-Y recorder. The digital data format facilitates post-measurement confirmation of data values and report creation.


High-precision temperature measurement even during high-speed sampling

Lets users perform high-precision temperature measurements even during high-speed sampling – ideal for performing combined voltage and temperature measurements.


Comprehensive built-in trigger and timer functions

Using a combination of trigger and timer functions eliminates superfluous data and enables capture of only the required data.

Setting example 1

To perform measurement over a four-day period starting January 10
Timer setting Date and time Start setting January 10 00 hours 00 minutes
Stop setting January 14 23 hours 59 minutes
Trigger setting Start trigger Off
Stop trigger Off

Setting example 2

To perform measurements of abnormal signals during device operations
Timer setting Daily cycle Start setting 09 hours 00 minutes
Stop setting 17 hours 00 minutes
Trigger setting Start trigger Level CH 1 (3 V Rising)
Stop trigger Level CH 1 (2 V Falling)
Repeat On

Setting example 3

To perform measurements every 20 minutes
Timer setting Hourly cycle Start setting 00 minutes 00 seconds
Stop setting 20 minutes 00 seconds
Trigger setting Start trigger Off
Stop trigger Off

Setting example 4

To perform measurements for a period of one hour, every four hours, daily

With the timer set to daily cycle status, data is captured repeatedly for one hour every four hours.

Trigger setting Start trigger Off
Stop trigger Scheduled time (one hour)
Repeat On (Repeat interval: 4 hours)
Timer settings Timer mode Off, Date and time, Daily cycle, Hourly cycle
Trigger settings Start source setting Off, Level value, External input
Stop source setting Off, Level value, External input, Scheduled time
Pre-trigger 0-100%
Repeat capture On, Off and Repeat interval

High-voltage measurement capability

The wide 500 V range enables 100 to 240 VAC power supply voltage waveform measurements. Using logic input and a clamp meter simultaneously allows measurement of a device’s power supply voltage and current concurrently with sequential control of various points.


Built-in, large-format 5.7-inch color LCD for easy-to-read waveforms

The bright, easy-to-read large-format 5.7-inch color TFT LCD provides vivid, easy-to-read waveform displays. Cursor keys enable fast, easy control and setup. The waveform display can be scrolled at high-speed – 10 ms/DIV.


Free Running display for waveform-checking without the need for data capture

The Free Running display lets users check input signal waveforms even before measurements begin. Since waveforms are displayed on each setup screen, users can make settings while viewing the waveforms.


Easy PC measurement via USB; remote monitoring via Ethernet web server and FTP functions

The USB and Ethernet connections enable transfer of captured data to your PC and setup and control of the GL900 from a PC, even without the PC software provided standard with the GL900.

Web server/FTP server functions

Waveform display and GL900 setup operations can be performed via a web browser (e.g., Internet Explorer). In addition, data files captured to the GL900’s internal memory or to a USB memory stick can be transferred or deleted from the PC.

USB drive mode

When your GL900 is connected to your PC via the USB interface, the GL900 can be operated in USB mode to enable fast, easy data transfers from internal memory to the PC.

NTP client function

Simply connect the GL900 to an NTP server via an Ethernet connection to synchronize GL900 time with NTP server time at periodic intervals


 

Dedicated software for real-time data capture

Three measurement screens are provided to allow selection of the screen that best suits measurement needs.
The Replay screen provides a Zoom screen feature to enable enlarged display of specific sections of long-term measurement data.


 

Simple operations for anyone

Easy-to-use software using icon keys for intuitive operations


Convenient functions

Various convenient data-processing functions are built in.

  • Direct to Excel function
    This function enables measurement data to be written directly to an Excel file.
  • Search function
    This function enables searching for specific values in the captured data.
  • CSV batch conversion function
    This function enables batch conversion of multiple captured files to CSV file format.
  • Thumbnail function
    This function enables display of captured data files as thumbnails.

 

 

 

For full specifications please also see the PDF Brochure

GL900 Series

Technical Specs & Details

GL900 main unit specifications

ItemDescription
GL900-8GL900-4
No. of analog input ch. 8 ch 4 ch
External input/output Trigger input (1 channel), Logic input (4 channels) or Pulse input (4 channels), Alarm output (4 channels)
Sampling interval 10μs to 1 min
TIME/DIV 10 ms/DIV to 24 hour/DIV
Timer functions Date and time, daily cycle, hourly cycle
Trigger functions Type Start: Data capture starts when a trigger is activated; Stop: Data capture stops when a trigger is activated
Condition Start: Off, Input signal level (analog, logic/pulse), External*1, Scheduled time
Stop: Off, Input signal level (analog, logic/pulse), External *1, Scheduled time
Combination Input signal level: Level OR, Level AND, Edge OR, Edge AND
Mode H (Rising), L (Falling), Window In*2, Window Out*2
Alarm setting functions Rising, Falling, Window In*2, Window Out*2
Alarm output *1 Number of channels: 4, Open collector output (5V, 10 kΩ pull-up resistance)
Pulse input*1, *3 RPM mode 50 to 20 M RPM/F.S. (in steps of 1, 2, or 5)
Count mode 50 to 20 M C/F.S. (in steps of 1, 2, or 5)
Inst. Mode 50 to 20 M C/F.S. (in steps of 1, 2, or 5)
Calculation functions Statistical calculations *4: Average, Peak, Maximum, Minimum, RMS (2 calculations can be set simultaneously)
Other functions Search function, annotation input function
PC inteface Ethernet (10BASE-T/100BASE-TX), USB (High Speed supported) provided as standard
Ethernet functions Web server function, FTP server function, NTP client function
USB function USB drive mode (File transfer and deletion from internal GL900 memory)
Memory device Internal One million data points / Internal flash memory:Approx. 256 MB
External USB memory slot (High speed supported) *5
Display screens Waveforms + digital values, enlarged waveforms, digital values + calculation results, X-Y
Display unit 5.7-inch TFT color LCD
Operating environment 0 to 40℃, 5 to 85% R.H. (15 to 35℃ when using batteries)
Withstand voltage Between each input channel and GND: 1000 V p-p for one minute, between input terminals: 1000 Vp-p for one minute
Power supply AC adapter 100 to 240 VAC, 50 to 60 Hz
DC input 8.5 to 24 VDC
Battery pack *6 Option
Power consumption 42VA (when operating and charging battery with AC power) 40VA (when operating and charging battery with AC power)
External dimensions 232 x 150 x 80 mm (W x H x D), approx.
Weight (approx.) 1.1 kg (excluding AC adapter and battery) 1.0 kg (excluding AC adapter and battery)
Vibration-tested conditions Equivalent to automobile parts Type 1 Category A classification

Terminal block specifications

ItemDescription
GL900-8GL900-4
Number of input channels Fixed to 8 channels Fixed to 4 channels
Input terminal type Voltage BNC connector
Temperature M3 screw type terminal board *7
Input method All channels isolated Imbalanced input Simultaneous sampling of all channels
Measurement ranges Voltage 20, 50, 100, 200, 500 mV; 1, 2, 5, 10, 20, 50, 100, 200, 500 V F.S., 1-5 V F.S.
Temperature Thermocouples : K, J, E, T, R, S, B, N, W (WRe5-26)
Humidity 0 to 100% (voltage 0 V to 1 V scaling conversion) * with B-530 (option)
Input filter Off, Line, 5 Hz, 50 Hz, 500 Hz
Measurement accuracy *8 
(23°C±5°C) 
When 30 minutes or more have elapsed after power was switched on Filter : Line 
GND : connected
Voltage ±0.25% of F.S.
Thermocouple TypeMeasurement temperature rangeMeasurement accuracy
R/S 0°C ≦ TS ≦ 100°C ±7.0°C
100°C < TS ≦ 300°C ±5.0°C
R:300°C < TS ≦ 1600°C ±(0.05% of rdg +3.0°C)
S:300°C < TS ≦ 1760°C ±(0.05% of rdg +3.0°C)
B 400°C ≦ TS ≦ 600°C ±5.5°C
600°C < TS ≦ 1820°C ±(0.05% of rdg +3.0°C)
K -200°C ≦ TS ≦ -100°C ±(0.05% of rdg +3.0°C)
-100°C < TS ≦ 1370°C ±(0.05% of rdg +2.0°C)
E -200°C ≦ TS ≦ -100°C ±(0.05% of rdg +3.0°C)
-100°C < TS ≦ 800°C ±(0.05% of rdg +2.0°C)
T -200°C ≦ TS ≦ -100°C ±(0.1% of rdg +2.5°C)
-100°C < TS ≦ 400°C ±(0.1% of rdg +1.5°C)
J -200°C ≦ TS ≦ -100°C ±3.7°C
-100°C < TS ≦ 100°C ±2.7°C
100°C < TS ≦ 1100°C ±(0.05% of rdg +2.0°C)
N 0°C ≦ TS ≦ 1300°C ±(0.1% of rdg +2.0°C)
W 0°C ≦ TS ≦ 2000°C ±(0.1% of rdg +2.5°C)
Reference contact compensation accuracy : ±1.0°C
‡ Thermocouple diameters T: 0.32mm, others: 0.65mm
A/D converter 16 bits (out of which 14 bits are internally acknowledged)
Maximum permissible input voltage Between + and - input terminals 20 mv to 1 V : ±30VDC
2 V to 500 V : ±500VDC
Between input channel terminals 60 Vp-p
Between input channel terminal and GND terminal 60 Vp-p
Withstand voltage Between input channel terminal and GND terminal 1 minute at 1000 Vp-p
Between input channel terminals 1 minute at 1000 Vp-p
*1
Logic alarm cable (B-513) is required.
*2
Cannot be set for logic input
*3
Maximum input frequency: 50 kHz, maximum number of counts: 15 M C
*4
In real time or when Between Cursors has been specified (during Replay)
*5
1 file = 2 Gbytes (depends on the USB memory stick used)
*6
Please install two battery packs.
*7
Connections are made to both the BNC terminal and M3 screw terminal for the same channel.
*8
Thermocouple diameters T:0.32φ, others:0.65φ
*9
Operating temperature range: -25 to +80°C

Control software specifications

ItemDescription
Supported OS Windows 2000, Windows XP, Windows Vista (32-bit and 64-bit versions)
Functions GL900 control, real-time data capture, data conversion
Setting range Amp settings, data capture settings, trigger settings, alarm settings, other
Captured data Real-time data Binary: Sampling speed: 10 μs to 60 s
CSV: Sampling speed: 10 ms to 60 s
Data conversion Binary, CSV
Display information Analog waveforms, logic waveforms, pulse waveforms, digital values
File conversion Data between cursors, All data
2-screen function (Zoom) Display of current and past data
Display of statistics and history Display of maximum, minimum, and average values