The world's leading aluminum extruders now select Land Aluminum Extrusion Thermometer Systems as their preferred choice. LAND offers a complete new integrated range of thermometer systems dedicated solely to aluminum temperature measurement. These instruments contain unique-to-Land design features which provide inherent measurement stability and reliability.
Part Number: Aluminium Extrusion
Product Files

The world's leading aluminum extruders now select Land Aluminum Extrusion Thermometer Systems as their preferred choice. LAND offers a complete new integrated range of thermometer systems dedicated solely to aluminum temperature measurement. These instruments contain unique-to-Land design features which provide inherent measurement stability and reliability.

In the aluminum extrusion industry, product quality and operating profitability rely on efficient press operation. Press efficiency is increased greatly with accurate, reliable temperature measurement at critical points in the process:

  • The preheated die prior to installation in the press
  • The billet as it enters the press
  • The extrusion exiting the die
  • The extrusion at the quench exit

These instruments are based on time proven and established systems in the aluminum industry with more than 300 installations world-wide. They are high precision and provide measurement stability and reliability.

Preheated Die Temperature

Preheated_die_temperature

The Aluminum Die Thermometer (ADT) provides assurance that the die, which is preheated in a die oven, is at the correct temperature prior to being installed in the press. This ensures reduced die wear and improved press efficiency.

 
 

Billet Profile Temperature

Billet_profile_temperature

The Aluminum Billet Thermometer (ABT) provides continuous and highly accurate temperature measurement of the billet as it passes from the heater to the press. The system can accommodate the large variety of alloy types and degrees of surface roughness often encountered. The inherently fast response of the sensor enables temperature profiling (i.e. measurement of 'taper') immediately prior to the billet being loaded into the press. The ABT can be used with the new Landmark Graphic AE Processor for displaying a 'snap shot' of the temperature profile of aluminum billets prior to extrusion. The LMG AE processor is capable of capturing up to 150 data points from the ABT thermometer with the measurement interval configurable between 10 and 600ms, provided that a user adjustable threshold value is exceeded. This data set can then be displayed as a graphical profile of billet temperature on the LMG processor front panel. The processor automatically calculates the temperature taper of the billet; being the differential between two user defined cursor positions. Benefits of accurate profiling of billet temperatures include increased efficiency, better product quality and reduced die wear. A floppy disk is also available upon request containing a Procomm Plus Aspect file to enable downloading of Snap Shot billet temperature data into a spreadsheet format.

 
 

Die Exit Temperature

Die_exit_temperature

The new Aluminum Extrusion Thermometer (AET) provides responsive, continuous measurements on the extruded section at the die exit. AET utilizes proprietary technology to automatically compensate for alloy type, section profile and partial sighting of the section. The system has extremely high long term stability, and there are no elaborate setup requirements. A built-in laser targeting system provides accurate alignment on to the extruded section.

 
 

Quench Exit Temperature

Quench_exit_temperature

The new Aluminum Quench Thermometer (AQT) is designed specifically to provide accurate temperature measurement at the quench exit. Measurement at the quench exit verifies the cooling rates required to achieve correct mechanical properties on temperature-critical alloys. Using temperature measurements from the AET and AQT thermometers, in conjunction with an on-line input of ram or section speed, the LMG AE processor can accurately calculate quenching rates and provide these data to the operator, in a variety of display formats, and to the press/quench control system, via an output with user-configurable quench rate alarms. Sophisticated two-stage quenching systems can also be readily accommodated. This measurement is both automatic and continuous. A built-in laser targeting system also provides accurate alignment on to the extruded section.

 

 

The world's leading aluminum extruders now select Land Aluminum Extrusion Thermometer Systems as their preferred choice. LAND offers a complete new integrated range of thermometer systems dedicated solely to aluminum temperature measurement. These instruments contain unique-to-Land design features which provide inherent measurement stability and reliability.

In the aluminum extrusion industry, product quality and operating profitability rely on efficient press operation. Press efficiency is increased greatly with accurate, reliable temperature measurement at critical points in the process:

  • The preheated die prior to installation in the press
  • The billet as it enters the press
  • The extrusion exiting the die
  • The extrusion at the quench exit

These instruments are based on time proven and established systems in the aluminum industry with more than 300 installations world-wide. They are high precision and provide measurement stability and reliability.

Preheated Die Temperature

Preheated_die_temperature

The Aluminum Die Thermometer (ADT) provides assurance that the die, which is preheated in a die oven, is at the correct temperature prior to being installed in the press. This ensures reduced die wear and improved press efficiency.

 
 

Billet Profile Temperature

Billet_profile_temperature

The Aluminum Billet Thermometer (ABT) provides continuous and highly accurate temperature measurement of the billet as it passes from the heater to the press. The system can accommodate the large variety of alloy types and degrees of surface roughness often encountered. The inherently fast response of the sensor enables temperature profiling (i.e. measurement of 'taper') immediately prior to the billet being loaded into the press. The ABT can be used with the new Landmark Graphic AE Processor for displaying a 'snap shot' of the temperature profile of aluminum billets prior to extrusion. The LMG AE processor is capable of capturing up to 150 data points from the ABT thermometer with the measurement interval configurable between 10 and 600ms, provided that a user adjustable threshold value is exceeded. This data set can then be displayed as a graphical profile of billet temperature on the LMG processor front panel. The processor automatically calculates the temperature taper of the billet; being the differential between two user defined cursor positions. Benefits of accurate profiling of billet temperatures include increased efficiency, better product quality and reduced die wear. A floppy disk is also available upon request containing a Procomm Plus Aspect file to enable downloading of Snap Shot billet temperature data into a spreadsheet format.

 
 

Die Exit Temperature

Die_exit_temperature

The new Aluminum Extrusion Thermometer (AET) provides responsive, continuous measurements on the extruded section at the die exit. AET utilizes proprietary technology to automatically compensate for alloy type, section profile and partial sighting of the section. The system has extremely high long term stability, and there are no elaborate setup requirements. A built-in laser targeting system provides accurate alignment on to the extruded section.

 
 

Quench Exit Temperature

Quench_exit_temperature

The new Aluminum Quench Thermometer (AQT) is designed specifically to provide accurate temperature measurement at the quench exit. Measurement at the quench exit verifies the cooling rates required to achieve correct mechanical properties on temperature-critical alloys. Using temperature measurements from the AET and AQT thermometers, in conjunction with an on-line input of ram or section speed, the LMG AE processor can accurately calculate quenching rates and provide these data to the operator, in a variety of display formats, and to the press/quench control system, via an output with user-configurable quench rate alarms. Sophisticated two-stage quenching systems can also be readily accommodated. This measurement is both automatic and continuous. A built-in laser targeting system also provides accurate alignment on to the extruded section.

 

 

The thermometers and thermometer systems listed here are specially designed to solve temperature measurement problems in specific industrial applications. LAND are also willing to consider making 'customized' non-standard products, or even to develop a particular system from scratch to answer individual requirements. Talk to LAND about your own particular needs.

Click here to open Land Infrared's Application Solutions page

(opens in a new tab)

Online store by DBG Technologies, powered by LiveCube